Troubleshooting
Guide
The FOIL Ethernet filters do not require any special treatment. Connect the filter to a computing device and a
network (or second computing device) and the filter will autonegotiate the connection between the two and
should work seamlessly and invisibly. However, occasionally there is a communication problem or
network/software hiccup that interferes with network connectivity. And less frequently, there is a hardware
failure.
In the event that your FOIL Ethernet filter fails to work or stops working, follow these instructions:
NOTE: FOIL Ethernet filters pass Ethernet packets ONLY. They will NOT pass other signals such as the tones
or pulses used by network cable testers or digital phone signals that are not based on Ethernet (TCP/IP). The
ONLY way to test a FOIL Ethernet filter is to connect the filter to a computing device and a network (or other
computing device) and verify connectivity.
Step 1. Verify the filter is plugged in and the power supply is functioning. The power supply should be able to
provide 5VDC and at least 1 amp to the filter. If necessary, use a multimeter to check that the power supply
output is 5VDC or slightly higher.
Step 2. Check the input connector and make sure the pins are not bent and are properly aligned so they will
come in contact with the cable connector pins.
Step 3. Do the same for the output connector and make sure the pins are not bent and are properly aligned so
they will come in contact with the cable connector pins.
Step 4. Reset the computing device, network device and the filter at the same time, allow ample time for
everything to come back up and check for network connectivity. The filter can be reset by unplugging the
power supply for 5 seconds and then plugging it back in.
Step 5. If there is still no connectivity, try "repairing" the network connection on the computing device or force
the computing device to release its IP address and renegotiate with the network for a new IP address.
Step 6. If you are connected to a managed switch (eg Cisco switch), it is possible that the switch is turning off
the network connection because it sees the FOIL Ethernet Filter as an unauthorized network (the filter acts like
its own switch to minimize traffic through the fiber connection). You will need to check with your IT department
to see if they use Bridge Protocol Data Unit (BPDU) Guard or similar security feature. Alternatively, you can
test the filter by disconnecting from the managed switch and using two computers or network devices through
the filter instead.
Step 7. Finally, verify that your computing device, cables and network are functioning properly by directly
connecting the computing device to the network. You MUST use the same computing device, cables and
network connection to positively remove these variables as possible causes of the problem. For the cables,
you should either use an RJ-45 coupler to connect the cables together, or test each cable separately.
Step 8. If there is still no connectivity, then the filter may be faulty. It will be necessary for you to contact us and
arrange for an RMA number.
All FOIL Ethernet filters have a two year warranty from date of first sale.