djpower V-1 Manuale d'uso - Pagina 12
Sfoglia online o scarica il pdf Manuale d'uso per Attrezzature per DJ djpower V-1. djpower V-1 16. Spark machine
Anche per djpower V-1: Manuale di avvio rapido (2 pagine)
V-1 SPARK MACHINE Art.No.: 118428
7. Error
When Error Protections are activated, the unit stops working and heating system shuts off
automatically. LCD screen displays Error code.
Error
E0
Over temperature
E1
Heating failed
Over current
E2
protection of the
motor
E3
Thermocouple failed
Thermocouple tripped
E4
off
E5
No enough time
Over temperature
E6
inside the unit
E7
Step motor problem
The working
E8
frequency is
abnormal.
Cause
The temperature is since more
than 30s more than 700°C.
The device did not reach the
working temperature after 10 min.
Error of the motor.
Short circuit or wrong connection.
Open circuit or no connection.
Granules run out soon.
The temperature inside the unit is
higher than 60°C.
The step motor is not able to reset.
Electrical network frequency is
abnormal.
12 / 16