Altronix eBridge1600PCRM Manuale di installazione - Pagina 3

Sfoglia online o scarica il pdf Manuale di installazione per Ricevitore Altronix eBridge1600PCRM. Altronix eBridge1600PCRM 8. Ebridge plus

Altronix eBridge1600PCRM Manuale di installazione
Note: Caution: Once PoE connection is established between eBridge400/800/1600PCRM and eBridge100TM or eBridge100ST,
disconnecting the coax from eBridge100TM will not disable the PoE-compliant voltage from eBridge400/800/1600PCRM.
eBridge100TM or eBridge100ST can be reconnected, however, caution should be taken not to connect the coax wiring from
eBridge400/800/1600PCRM to any non-PoE device.
1. eBridge400/800/1600PCRM Receivers installation:
a.
eBridge400PCRM - Affix rubber pads to eBridge400PCRM for shelf installation (Fig. 5, pg. 6).
eBridge800/1600PCRM - Attach mounting brackets to the unit for rack installation (Fig. 4, pg. 6).
Affix rubber pads to eBridge800/1600PCRM for shelf installation (Fig. 5, pg. 6).
Unit should be located in proximity to ethernet switch/network, NVR or video server.
b. Connect structured cable from ethernet midspan or endspan device to RJ45 jack marked [100BaseT] (Fig. 2, pg. 3).
c.
Connect Coax cable to BNC connector marked [Coax] (Fig. 1, pg. 3).
2. eBridge100TM Transceiver installation:
a.
Secure unit to desired mounting surface with a proper fastening device utilizing the case's mounting hole.
Unit should be mounted in proximity of camera/device.
b. Connect structured cable from IP camera/device to RJ45 jack marked [100BaseT] (Fig. 2, pg. 3).
c.
Connect Coax cable to BNC connector marked [Coax] (Fig. 2, pg. 3).
3. eBridge100ST Transceiver installation:
a.
Secure unit to desired mounting surface with a proper fastening device utilizing the case's mounting hole (Fig. 2a, pg. 3).
Unit should be mounted in proximity of camera/device.
b. Connect structured cable from IP camera/device to RJ45 jack marked [PoE Out] (Fig. 2a, pg. 3).
c.
Connect Coax from eBridge receiver (eBridge400PCRM, eBridge800PCRM or eBridge1600PCRM) cable to BNC tether
cable marked [Coax] (Fig. 2a, pg. 3).
Note: eBridge400/800/1600PCRM is designed to accommodate Megapixel, HD720, HD1080 and VGA (SD) cameras. It is important to
note that some high resolution and high frame rate cameras may demand faster headend processing ability, such as a PC graphics card
to present a quality image. If the headend processing equipment is insufficient in speed, the image may show pixelation and latency.
It is advisable to pretest system if unsure. Alternatively, frame rate and resolution may be reduced to accommodate system equipment.
Fig. 1
eBridge800PCRM
(rear)
1
2
3
eBridge800PCRM
(front)
Fig. 1a
Coax Cable from
eBridge100TM or eBridge100ST
Data In
16
15
14
eBridge1600PCRM
(rear)
1
2
eBridge1600PCRM
(front)
eBridge400/800/1600PCRM
100
Base-T
4
5
6
7
Structured
Cable from
midspan/endspan
Data In
13
12
11
100
Base-T
3
4
5
6
Structured
Cable from
midspan/endspan
eBridge800PCRM
8
8
eBridge1600PCRM
10
9
8
7
100
Base-T
7
8
9
10
Coax Cable from
eBridge100TM or eBridge100ST
Data In
7
6
5
4
Data In
6
5
4
3
100
Base-T
11
12
13
Data In
3
2
1
Data In
2
1
14
15
16
- 3 -