DKM Motor Co., Ltd. FX3000 Manuale

Sfoglia online o scarica il pdf Manuale per Controllore DKM Motor Co., Ltd. FX3000. DKM Motor Co., Ltd. FX3000 2. Digital speed torque controller

DKM Motor Co., Ltd. FX3000 Manuale
Operation/Parameter Setting Procedure
■ Operation setting procedure
After wiring, set as follows.
① Input AC power(Terminal CN1 #1, #2)
Display lights up(Rotation speed)
② Operation switch→RUN
Motor operates if the switch is
RUN position
③ Operation switch→STOP
Motor stops if the switch is
STOP position
④ Rotation direction setting
CW/CCW Switch
CW/CCW Switch
MOTOR
MOTOR
Clockwise
Counter Clockwise
at 'FWD'
at 'REV'
※ Caution
Please change rotation direction after the motor
completely stops.
⑤ Rotation speed setting
RPM changes if turn the dial.
If turning the dial slowly,
Decrease
Increase
RPM increases/decreases by 1r/min.
in speed
in speed
If turning the dial quickly, the speed
variation becomes large.
RPM DISPLAY
Setting data will change automatically
after 2 seconds.
If the power turns on again,
it operates with the final setting value.
※ Please refer to 'CW/CCW signal connection' in the
manual if operating RUN/STOP extemally.
Display/ Setting
■ Entire Transition Diagram
RPM display
Speed or Torque setting
with the dial
Mode Button
Parameter
PR01
PR01
DIAL
Mode Button
PRSF
PR07
※Speed Control P, I gain
- Parameter to determine the responsibility of speed control.
- Vibration and hunting phenomenon occurs if the value is too large.
■ Parameter setting procedure
After wiring, set as follows.
① Input AC power
Display lights up(Rotation speed)
② Select parameter mode
MODE Button
Enter into the parameter mode as pressing the
MODE button while motor is stop condition.
(STAND-BY)
"Pr01" appear at display
(Parameter mode)
③ Parameter Data
Turn the dial and choose the parameter
number which user wants to (Pr01~Pr07)
④ Change Parameter Data
ENTER
Press the dial(SET button) to enter
the parameter data.
PUSH
(Briefly)
CHANGE
DATA flickers and switches to changeable
status if pressing and holing the dial
(SET button) during 2 sec.
PUSH
(Hold-2sec.)
CHANGE
Data value will be changed and possible to
set the desired value if the dial is rotated
toward CW/CCW.
CW/CCW
(Roration)
COMPLETE
Data stop blinking and finish the setting when
pressing and holing the dial(SET button)
for 2 sec.
PUSH
(Hold-2sec.)
⑤ Operation Mode
MODE Button
'0' output at display
Press the MODE
(RPM)
button to enter the
(operation mode)
operation mode.
■ Parameter Contents
Parameter
Function Range Standard
Remark
NO. Display
Value
Time(second) to reach
Pr01 Acceleration
1
0~15.0
0.1
the set speed
Time
Rotation
0 : Clockwise
2
Pr02
0, 1
0
Direction
1 : Counterclockwise
3
Pr03
Gear Ratio 1~999
1.0
Input gear ratio
Control
0: Speed Control
4
Pr04
0, 1
0
Mode
1: Torque Control
5
Pr05
P Gain
0~255
100
6
Pr06
I Gain
0~255
50
Parameter
Reset when pressing and
-
0
Pr07
7
Reset
holding the SET button
Software
Display the
PrSF
SF
-
-
Version
software version
DKM DIGITAL SPEED TORQUE CONTROLLER
FX3000 manual
We appreciate you for purchasing products of
DKM Motor co., Ltd. Before using the product you have
purchased, check to make sure that it is exactly
what you ordered. Then, please use it following the
instructions below.
SAFETY INFORMATION
Alerts declared in the manual are classified to Danger,
Warning and Caution by their criticality
DANGER indicates imminently hazardous situation which,
DANGER
!
if not avoided, will result in death or serious injury.
WARNING indicates a potentially hazardous situation which,
WARNING
!
if not avoided, could result in death or serious injury.
CAUTION indicates a potentially hazardous situation which,
CAUTION
!
if not avoided, may result in minor or moderate injury.
DANGER
!
There is a danger of occurred shock in the input/output terminals so please
never let your body or conductive substance is touched.
!
WARNING
1. Do not put around the explosive atmosphere, gas to be burnt,
corrosive air, the location to be wet and combustibles.
If not, there will be the electric shock and the fire.
2. Installation, connection, operation, maintenance and diagnostic
operation should be carried out by the person who has expertise.
3. Use the product after turning off the power.
It may cause an electric shock.
4. The power cable and the lead wire should not be bent, pulled and
inserted by force. If not, the electric shock and the fire may occur.
5. In case of the motor and controlling unit are attached to the machine,
never touch with hand or connect with the earth. If not, the electric
shock may take place.
6. Within the 30 seconds after the power off, do not touch the output
terminal of the controlling unit. If not, the electric shock may occur
because of the residual volts.
!
CAUTION
1.
The motor and the controlling unit should be used only by the
designated compounding. If not, the fire may occur.
2.
Do not operate with the wet hands. The electric shock may occur.
3.
In case of moving, do not catch the output shaft, connecting part or
the lead wire. There may be the injury by the drop.
4.
The motor should be used after it is fixed tightly. If not, the injury
and/or the damage of the unit may occur.
5.
Do not touch the rotating part (output shaft, cooling fan) in running.
It could be cause of injury.
6.
If there are abnormal cases, turn off the power at once. If not, there
will be the electric shock, injury and the damage.
7.
Do not touch the motor for a while, if the motor' s surface temperature
exceeds 90℃.
8.
Be sure to set the switch STOP before connecting to the power.
9.
Make sure to check the rotating direction before connecting the
machine. If not, the injury and/or the damage of the unit may occur.
10.
Use products only according to the specification of motor and
controlling unit. If not, there will be dangerous fire, electric shock,
injury and/or damage of the unit.
11.
Make sure to install the overload device because the protection device
is not attached to the motor. It is desirable to install other protection
devices other than overload protection device to prevent fire.
SPECIAL FEATURES
■ Possible to control speed and torque.
■ Possible to control the speed and torque of the motor simply by
connecting motor and control unit with connector and inputting the
AC terminal to the power source.
DKM Motor Co., Ltd.
Head Office / Factory
4F., Incheon Techpia Na-Bldg.,
Geobukro 17, Seo-gu, Incheon, Korea
Tel. +82.32.574.7788 Fax. +82.32.578.7787
www.dkmmotor.com
Head Office / Factory
4F., Incheon Techpia Na-Bldg.,
Geobukro 17, Seo-gu, Incheon, Korea
Tel. +82.32.574.7788 Fax. +82.32.578.7787
■ Display the current rotation speed(r/min) and torque(%).
■ Possible to control speed and torque easily with the front panel dial.
■ Possible to operate various functions by setting the parameter.
BEFORE USE
■ Check specifications which you ordered such as voltage,
output and so on.
■ Make sure a motor item whether the motor can be applicable with
DSKM controller.
■ Avoid the place in vibration, deep Impact, lots of dusty, inflammable
gas and corrosive gas.
■ Use ambient temperature(-10 ℃ ~ 40 ℃) and ambient humidity
(85% maximum and avoid direct sunlight, moisture and greasy place.
■ Install motor and controller as closely as possible. (within 2m)
CONTROLLER CODING SYSTEM
FX3000
006
S
Controller Model
OUTPUT
TYPE
S: Speed Motor
003: 3W
030: 30W
T: Torque Motor
006: 6W
040: 40W
010: 10W
060: 60W
015: 15W
090: 90W
020: 20W
120: 120W
025: 25W
180: 180W
Initial setting mode is speed control. Please change '0'(speed mode) to '1'
(torque motor) after selecting parameter 'Pr04'(control mode) if using torque motor.
Regarding changing method, please refer to 'Parameter setting procedure' and
'Display/Setting' in the manual.
Specifications
FX3000-□□
Model Name
Rated Voltage
1Ø AC 220~240V 50/60Hz ±10 %
Allowable Current
Below 6 A
Control Function
Speed Control, Torque Control
Control System
Phase Control
Speed
50Hz : 90~1400r/min
Control
60Hz : 90~1700r/min
Setting Range
Torque
0 ~ 100 %
Control
Speed Setting
Setting by Volume
±5%(Standard Value)
Speed Variation
Motor Output
3W~180W
-10C°~ 55C°
Ambient Temperature
35 ~ 85%RH (Without condensation)
Ambient Humidity
Over DC 500V 100MΩ
Insulation Resistance
(between power supply and external terminal)
AC 1500V 1minute
Dielectric Strength
(between power supply and external terminal)