1.1 OPERATING MODES

This battery backup system consist of a control board (2340-010), motor and power supply (batteries)
providing a completely redundant drive system to open the gate should a power outage occur. This
backup system is not designed to maintain continuous gate operation; rather it provides a convenient
method to open a gate during adverse conditions. If continuous gate and access control system
operation is required, refer to the DoorKing Model 2000 Inverter / Backup Power System.
When installed in slide or swing gate operators, the backup system can be set to operate in either a
manual (for residential applications) or automatic (for apartment complexes, gated communities, etc.)
mode of operation. The system will only operate in automatic mode when installed in a barrier gate
operator.
Manual Open (slide, swing gates only) – Residential Only
Manual mode is designed for residential applications only. In manual mode (switch 1 OFF), the
battery backup system will not open the gate if a power failure occurs until a manual input, either from
a wired push button or RF transmitter, is received. This allows the gate to remain closed upon a loss
of AC power, but provides a method to open the gate when desired. In manual mode of operation,
the RF receiver is connected directly to the battery backup control board and is powered by this board
(see page 18).
During normal operation, when the relay in the radio receiver closes (a valid
transmitter code has been received), this "signal" is passed through the backup system control board
through terminal 4 and is feed directly to the gate operator main control board open input. If a power
failure occurs, the radio receiver is powered from the batteries maintaining its operation. When a
valid RF transmitter code is received under these conditions, the backup control board signals the DC
motor to start and the motor will run for the set run time. A switch closure (push button) across
terminals 1 and 2 on the backup control board will have the same result.
NOTE: The RF transmitter will open the gate provided that a stand-alone type receiver is in use. If
the gate system uses a receiver that outputs the transmitter code in weigand format to an access
controller (such as DoorKing models 1833, 1835, 1837 or 1838), then opening the gate from the RF
transmitter under power outage conditions will not be possible with this system.
Automatic Open – Apartment Complexes, Gated Communities, Etc.
In automatic mode (switch 1 ON), the battery backup system will automatically open the gate or raise
the barrier arm approximately 2-3 seconds after a loss of AC power. Automatic mode is always used
for gates in general access applications such as gated communities, apartment complexes, etc.
Automatic mode must be used when the system is installed in barrier gate operators.
Automatic Restart
Once AC power is restored, the battery backup board can be set to automatically "re-key" the gate
operator (switch 3 ON) to establish normal operation, or can be set to require an input (switch 3 OFF)
before the gate operator resumes normal operation.