Alula RE116-U Manuale - Pagina 2

Sfoglia online o scarica il pdf Manuale per Sistema di sicurezza Alula RE116-U. Alula RE116-U 4. Wireless siren

USE THIS MANUAL IF USING THE SPECIAL TRANSMITTER TO SEND
ENROLLMENT
Open the Siren battery door, giving access to the programming switches.
Power the Special Transmitter with its battery.
Power the Siren with its battery.
Enrolling Special Transmitter into Siren – to send panel siren signals to Siren

Put Siren Function in ENROLL Mode.
HIGH VOLUME STATUS BEEPS
low volume status beeps
 Press and release the Special Transmitter tamper switch.
The Siren will beep 4 times, indicating enrollment.
 IMPORTANT: Put cover on Special Transmitter.
 Put Siren Function Switches in RUN Mode.
Select low volume or HIGH VOLUME status beeps
HIGH VOLUME STATUS BEEPS
low volume status beeps
DO THESE STEPS ONLY IF PANEL IS A GE SYSTEM.
Enrolling Siren in Panel – to monitor both Special Transmitter and Siren
(Siren only talks GE wireless):
• If you want to have Siren monitor the Special Transmitter
In Step 2 above, instead of using the Special Transmitter's tamper switch to
enroll, pull and replace Special Transmitter battery. Siren will beep 8 times.
❖ IMPORTANT: You must NOT enroll Special Transmitter in panel.
Panel will go CRAZY with alarms.
After step 4 above, enroll Siren into GE panel:
With Panel in enroll mode...Cycle tamper switch on Siren. Enroll in Group 10.
Put cover on Siren.
Plug Siren in wall.
System is ready to operate.
MULTIPLE SIRENS:
You can enroll multiple sirens in one system. Just enroll the same single original
Special Transmitter in the 2
TO CHECK SPECIAL TRANSMITTER  SIREN LINK:
Tamper, or install the battery in the Special Transmitter  Siren will beep twice.
RE116-U_47-0051-02_RevA
Tech Support Line: (888)88-ALULA (888) 882-5852
SIGNAL TO SIREN
1
2
1
2
1
2
1
2
nd
Siren. Simply repeat Steps 1-4 with the 2
Page 2 of 4
alula.net
ENROLL
RUN
ENROLL
RUN
nd
Siren.
30-Apr-18