3. TECHNICAL SPECIFICATIONS

Power supply:
Frequency:
Operating temperature:
Maximum output power:
Average range:
Works exclusively with motors without built-in radio control.
Works with all AC series transmitters included in the ALUPROF S.A. offer.
Possibility to program up to 20 transmitters, Each next transmitter will erase the first one.
Company reserves the tolerance of catalog data due the different conditions usage.
4. CONNECTION OF THE TRANSMITTER
If no external switches are connected to the control unit, you must put the jumper between "STOP" and "GND".
2
PROGRAMMING MANUAL FOR THE AC 277-01 CONTROL UNIT
230 VAC / 50 Hz
433.92 MHz
~ -20°C - ~ +55°C
750 W
120 meters (in open space), 20 meters (inside buildings)
POWER
- power connectors
MOTOR
- motor connectors
PHOTOCELL
- photocell connectors
MASTER CONTROL
- external switch connectors
EXT-MANUAL
- external switch connectors
SAFETY EDGE
- safety edge connectors
L
- phase wire
E
- protective wire
N
- neutral wire
UP
- UP direction
DOWN
- DOWN direction
COM
- power connector
+15
- Power supply: +15 V
+24
- Power supply: +24 V
S/STOP
- STOP
GND
- ground
We reserve the right to any technical change.
Valid on 2021.06.07