6.4. Trigger Timing
t1
Effective trigger input pulse
From the rise of the external trigger input to the
t2
fall of the trigger signal passed to the sensor
(Delay due to the photocoupler)
From the fall of the trigger signal passed to the
t3
sensor to the start of exposure
t4
Time required for data transfer
t5
(from the sensor to the FPGA)
t6
Trigger input prohibition period
※1H=12.96μsec.
※When input triggers continuously, please ensure that the trigger interval is more than t6.
items
Exposure time
- 13 -
Required time
>10μsec.
<1μsec.
Max 0.13μs
Exposure time = The setting value of the
Shutter speed*1H
(9+Effective Vertical pixels)*1H
t2+t3+t4+t5