5. Connect the Camera
5-1 How to connect a camera
5-2 Shutter Speed
Shutter speed can be changed on the standard viewer software ART-Viewer.
The shutter speed is set directly on the sensor register, so please refer to the following formulas for the real exposure
time.
Model
Method
Range:1~16383(Exposure Time:1/26747~0.61 sec)
0134AR-WOM Series
Exposure Time=(1280+108) × Shutter Value × 1/37.125 [μsec]
at 37.125MHz
- 9 -