TROUBLESHOOTING TIPS

• Do not reset the breaker multiple times.
• If the unit is overloaded, the breaker will trip, shutting off the driver
and lights.
• If the breaker reset button has been held down by hand or any type of
pressure, such as duct tape, or if the breaker has been reset multiple
times without troubleshooting, the unit will:
- Burn the driver bobbin.
- Burn the thermal or magnetic breaker.
- Burn the driver lead wires due to high amperage caused by overload.
- Short circuit in line which will not allow the breaker to reset.
- Damage the lighting.
1
Turn off power before beginning. Check for any twisting or damage
to the circuit in the LED lightstrip. If there is excessive damage and
the circuit is broken, the lightstrip must be replaced.
2
Check for metal particles or other foreign objects causing the short.
3
Check to make sure cuts in the lightstrip are clean and not frayed,
causing positive and negative copper pads to touch.

CONTINUITY TEST

A continuity test is performed to determine if electricity can pass
through two points on an electrical circuit. This helps identify shorts
or malfunctions in the luminaire. Use a multimeter or continuity
tester to perform the steps below.
• Always perform a continuity test before connecting to power source.
• Malfunctions are not always as obvious as the lights not turning on.
• A short or malfunction in the line or luminaire will cause damage over
time, irreparably damaging the lighting and voiding warranty.
1
Turn off power before beginning. Verify power is off by using a non-
contact circuit tester (by others). Touch the probe of the tester to
the positive wire of the power source. The tester will light up if an
electrical current is detected.
2
Setup your multimeter tester (by others). First, insert the black
probe lead into the COM jack, then insert the red probe lead into
the VΩ jack.
1170 N Red Gum St, Anaheim, CA 92806
aluz.lighting
© ALUZ All Rights Reserved. ALUZ reserves the right to make changes or withdraw specifi cations without prior notice.
A1 Series | Surface
ZIBI Standard Dynamic White
(A1-ZIBI-STN-DWH)
2
1
866.ALUZ.LTG | 714.535.7900
3
Touch the red probe to the luminaire extrusion and the black probe
to the ground wire (green). If the luminaire is properly grounded,
the multimeter will beep, flash, or read 0Ω (ohms). If there is no
conductive path, the multimeter will not show any feedback.
Troubleshoot to identify the malfunction in the ground wire.
1
2
(
3
4
5
4
Touch the red probe to any wire and the black probe to each other
wire. Repeat process for each wire. If a conductive path is formed
between any of the wires, the multimeter will beep, flash, or read
0Ω (ohms). Troubleshoot to identify the malfunction in the line.
If there is no conductive path, the multimeter will not show any
feedback.
Example: Check for continuity between Wire 2 and Wire 4
1
2
(
3
4
5
5
Touch the red probe to the luminaire housing and the black probe
to each wire except ground. If a conductive path is formed between
the housing and any of the wires, the multimeter will beep, flash,
or read 0Ω (ohms). Troubleshoot to identify the malfunction in the
line. If there is no conductive path, the multimeter will not show
any feedback.
1
2
(
3
4
5
6
Set multimeter to AC voltage and test power source. Confi rm the
correct voltage before connecting luminaire to power source. If the
voltage reading is more than 1 volt greater than the marked output
voltage, there is a problem with the power source or driver.
7
Connect luminaire to power source. If LEDs do not turn on,
troubleshoot to fi nd the problem in the line.
Page 12 of 13
Troubleshooting & Continuity Test
)
)
)
Installation Instructions
9 / 11 / 2023 / Rev 4