1- Warnings
-Using the equipment without following the manufacturer's instructions
may affect the device's safety requirements. To ensure that the device
operates correctly, only probes supplied by AKO should be used.
-The unit must be installed in a location protected from vibrations, water
and corrosive gases, where the ambient temperature does not exceed
that shown in the technical data.
-To ensure a correct reading, the probe must be situated in a location
without any external heat influences except for the temperature which
is being measured or controlled.
-The power supply circuit must be provided with a main switch rated at at
least 2 A, 230 V, located close to the equipment. The cables will enter
through the back and should be type H05VV-F or H05V-K.
-The gauge will depend on local regulations, but should in no case be less
2
than 1 mm .
-Connecting wires for the relay contacts should be sized 2.5 mm .
-Between -40 ºC and +20 ºC, if the probe NTC is prolonged till 1.000 m with a
2
mínimum of cable 0,5 mm , the maximum deviation will be of 0,25 ºC
(extension cable for probe ref. AKO-15586)
NOTE: Equipment not compatible with AKO-14917 (external communication
module) and AKO-14918 (programming key)
2- Installation
12 4 m m
3- Wiring
The probe and its cable should NEVER be installed in the same conduit
as power, control or supply cables.
AKO-D16323
1
2
3
4
5
6
7
8
9
10
11
12
13
FAN
AUX
AUX.
CRANKCASE HEATER
COOL
AUX
S1: Probe 1, temperature in the chamber or cabinet.
Operation as per
S2: Probe 2, defrost.
AUX.
parameter P6
DI1/DI2: Digital Input 1 / Digital Input 2
4- Operation
FAN relay ON
COOL relay ON
DEF relay ON
Alarm ON
Temperature
indication
2
UP (N) /SET key
DOWN (Q) key
Terminal blocks
Access to set point and Stand-by
5 sec.
Keep
UP / SET
pressed
Temperature
Release
Indication
SET to go to
Stand-by
I max.:
16 A
Programming Menu (parameters)
L N
After 20 seconds with no key being pressed, the equipment will return to the previous level. If you are on level 3, the changes will not be saved.
OUT OF
PROGRAMMING
PROGRAMMING
20 sec
Press
UP/
SET
>10 sec.
Temperature
Level 1
indication
Menus
OK
Press
Press
UP/
UP/
SET
SET
<5 sec.
repeatedly
UP(N) /SET key
Pressing for 5 seconds activates Standby mode, pressing for 2
seconds returns the equipment to normal mode. In Standby mode,
the equipment performs no actions and only the AKO indicator is
displayed on the screen.
Pressing for 10 seconds goes to the programming menu.
In the programming menu, pressing for 5 seconds goes to the level
displayed or, during the setting of a parameter, accepts the new value.
In programming menu, pressing briefly allows you to scroll through the
various levels or, during the setting of a parameter, to change the value.
DOWN (Q) key
In programming menu, pressing briefly allows you to scroll through the
various levels or, during the setting of a parameter, to change the value.
5- Start-up
On power-up, the equipment will start in Wizard mode (InI / 1
flashing), select the most appropriate application using the UP /
DOWN keys and press SET.
1: Multipurpose
2: Frozen
4: Fresh fish
5: Soft Drinks
7: AC
The wizard will configure the parameters of the equipment for the
chosen application (see table "Default settings by application").
10 sec.
t
Release SET
to access
programming
20 sec
20 sec
Change
Change
Parameters
Menu
OK
OK
Press
Press
Press
Press
UP/
UP/
UP/
UP/
SET
SET
SET
SET
<5 sec.
>5 sec.
<5 sec.
<5 sec.
Level 2
Level 3
Parameters
Values
OK
Press
Press
UP/
UP/
SET
SET
repeatedly
<5 sec.
3: Fruits and vegetables
6: Bottle racks
Change
value
OK
Press
Press
UP/
UP/
SET
SET
<5 sec.
<5 sec.