Sfoglia online o scarica il pdf Istruzioni per l'uso per Generatore portatile AIO CM1-AIO. AIO CM1-AIO 16. Ozone generator

AIO CM1-AIO Istruzioni per l'uso
- Do not stick the air inlet or outlet to the wall and avoid obstructing them.
2. Standard aromatherapy
User can enable or disable the aromatherapy / vaporizer by pressing the Aromatherapy
button (D). Single press enables the aromatherapy module, second press disables it. When
the aromatherapy is working there is a green LED above the button.
NOTE: ​ Follow the instructions for starting and using essential oils described in section 4.2
3. Ozonation
Ozone generator has 4 working modes, enabled by buttons.
The time selector knob (A) has 8 positions which can be selected by turning the knob.
Selected position is indicated by a little mark on the knob itself.
Available time settings are: 5 minutes, 10 minutes, 15 minutes, 30 minutes, 1 hour, 1,5 hour,
2 hours and constant.
NOTE: ​ O zone in high concentrations may be harmful, although it is not considered a
carcinogen or highly dangerous element, if it can be irritating to the respiratory tract with
misuse.
For this reason, follow the recommended instructions carefully:
- SEE instructions in section 7
- The night mode will be used for intense cleaning of those rooms, halls or instances,
without the presence of people or animals.
- Once the configured program has been completed, you will have to wait minimum 30
minutes to be able to access the worked area normally.
- You should not program the continuous mode if you cannot supervise the device.
- If you program continuous mode and you sense ozone outside the room where the
device is operating, ventilate the room and turn off the device.

4.3.3 HOW TO SET A TIME OF OZONATION?

For a ​ f ast intense cleaning​ we need to generate 1 ppm of ozone so we will make the
following calculation:
(M3 of our room) x 0.321= Min. working time
Example:
For a 30 m2 room with a height of 2.5 meters would be:
(30 x 2,5) x 0,321= 24,0 min. - so we will program the machine to maximum 30 minutes.
For an ​ i ntensive deep cleaning​ we need to generate at least 5 ppm of ozone so we will
make the following calculation:
(M3 of our room) x 1,605 = Min. Working time