ACP P2001401M Informazioni tecniche - Pagina 4
Sfoglia online o scarica il pdf Informazioni tecniche per Attrezzature per alimenti commerciali ACP P2001401M. ACP P2001401M 7. Commercial microwave
Component Testing Procedures
To avoid risk of electrical shock, personal injury, or death, disconnect power to oven and discharge capacitor
before servicing, unless testing requires it.
Illustration
Controller board
P1 connector used
for touch panel
ribbon
Error Code Table
Usage Test
The Usage Test is used to access Magnetron Hours, Magnetron Cycles and Door Cycles. Use the following
procedure to access the data:
1. Open door.
2. Press and hold pad 3 for five (5) seconds.
NOTE: After five (5) seconds, SErv illuminates in the display.
3. Press pad 1 for Magnetron Hours.
4. Press pad 2 for Magnetron Cycles.
5. Press pad 3 for Door Cycles.
16500038
Component
All Models
Line voltage to control board
E1 (RD) —T1 (WH) triac ............................
Output drive voltage to triac
Triac terminals .............................................
Gate (BR) —T1 (WH) ................................
120 VAC line voltage
Fan relay (controls blower motor, antenna
motor(s), and oven light)
Control board ...............................................
Terminals T1 (WH) —J2-3 (RD) ................
Control board ...............................................
Terminals E1 (RD)—E4 (PK) .....................
Error Code
F1
F2
F3
F4
F5
F6
Test
Corrective Action
Replace HV/LV Board
Replace HV/LV Board
Replace HV/LV Board
Replace HV/LV Board
Replace Touch Panel
Replace HV/LV Board
4
Results
Line voltage (All Conditions)
0 VAC (Idle and Standby)
0.2 VAC (Cook)
Line voltage (Idle)
0 VAC (Standby and Cook)
Line voltage (Idle)
0 volts (Standby and Cook)
July 2012
©2012 ACP, Inc.