AC800 V2.00
System Setting
Input password 111111 to enter "System. Setting". In system setting, Language, Calibration, Database, Unit set,
Empty container weight set, Component testing and owner information will be displayed or reconfigured.
Calibration: Even though the machine is equipped with calibration weight for quick and easy calibration, it is
recommended to have a professional technician only to perform calibration of load cells, pressure transducer, and
temperature sensor.
Warning: Not calibrating the machine correctly can have serious consequences on the machine and/or vehicle
A/C system.
Database: The technician can access the database of refrigerant, oil volume of different car makes and models.
Record: Record total operations of recovery, vacuum, oil injection and charge. Can reset to re-record. A dynamic
code is needed for access.
Unit settings: To set metric or imperial unit of measurement. In the interface of "unit set", values of each sensor
of the equipment are displayed for equipment diagnosis purpose.
Empty container weight set:
The total load cell reading equals the sum of empty container weight and net refrigerant/oil content value. Thus,
increase/decrease empty container weight, can correspondingly decrease/increase refrigerant/oil value displayed
in the main operation interface.
Component test:
The technician can activate and deactivate different electrical components of the machine. This is for quick and
easy diagnosis and troubleshooting.
Please note:
Only qualified technician (with special password) is allowed to access this function, not performing this test
correctly could cause damage to the machine or injury to the operator.