FAULT
No sound on left, right or
both channels.
Loud humming sound
through speakers.
Output sound is either
too loud, too quiet or
sound is distorting.
Output sound is either
too loud, too
quiet or sound is
distorting.
Page | 6
POSSIBLE CAUSE
A loss of connection between your
Turntable and the Phono Stage or
between the Phono Stage and your
Amplifier due to loose connections
or damaged cables.
Loose, missing or damaged Ground
wire connection.
MM/MC Switch is incorrectly set.
Incorrect input being used on your
Amplifier or Receiver.
SOLUTION
Ensure you have properly connected
your RCA and Phono cables. Also
check that your cables are not
damaged or faulty and replace if
required.
Ensure your ground wire is properly
and securely connected to both your
turntable ground terminal and the
Phono Stage GND terminal. Replace
your ground wire if damaged.
Check the specifications of the
cartridge in use with your turntable
and set MM/MC switch accordingly.
Only plug the output of the Phono
Stage into a LINE input. Never