DOCOL 00474206 Manuale di installazione - Pagina 3

Sfoglia online o scarica il pdf Manuale di installazione per Cucina e accessori; sanitari per il bagno DOCOL 00474206. DOCOL 00474206 8.

Maintenance
MAINTENANCE - 00474106
PROBLEM
PROBABLE CAUSE
Water does not
Water supply interrupted.
flow or flow rate
Angle stop valve closed.
too low. Solenoid
Angle stop filter clogged.
valve produces an
Aerator clogged.
audible "CLICK".
Batteries low. Red LED blinks
once every 1 second.
Batteries assembled with
Water does not
inverse polarities.
flow. Solenoid
Connection failure between
valve no produces
sensor an solenoid valve.
an audible
"CLICK".
Sensor cable is damaged.
Sensor damaged.
Object in front of sensor range. Remove the object.
Water flows
continuously
Solenoid valve damaged.
(leak)
Angle stop valve not installed.
Flow volume too
high.
Angle stop valve totally opened. Adjust the flow.
MAINTENANCE - 00474206
PROBLEM
PROBABLE CAUSE
Water does not
Water supply interrupted.
flow or flow rate
Angle stop valve closed.
too low. Solenoid
Angle stop filter clogged.
valve produces an
Aerator clogged.
audible "CLICK".
No power is being supplied.
Power switch not connected in
Water does not
the power supply.
flow. Solenoid
Power switch not connected in
valve no produces
the sensor.
an audible
"CLICK".
Sensor cable is damaged.
Sensor damaged.
Object in front of sensor range. Remove the object.
Water flows
continuously
Solenoid valve damaged.
(leak)
Angle stop valve not installed.
Flow volume too
high.
Angle stop valve totally opened. Adjust the flow.
14
SOLUTION
Check/open supply pipe.
Open stop valve.
diagram 10
Clean or replace.
diagram 11
Clean or replace.
diagram 12
Replace the batteries. Install the
diagram 6
bateries exactly as illustrated.
Install the batteries exactly as
diagram 6
illustrated.
Conect the sensor cable in the
solenoid valve cable.
Contact the Authorized Distributor
in your country.
Contact the Authorized Distributor
in your country.
Contact the Authorized Distributor
in your country.
Install and adjust the flow.
diagram 3
diagram 10
SOLUTION
Check/open supply pipe.
Open stop valve.
diagram 7
Clean or replace.
diagram 11
Clean or replace.
diagram 12
Check the main power is turned
ON.
Plug the power switch cable
diagram 6
correctly.
Plug the power switch cable in
diagram 6
the sensor cable.
Contact the Authorized Distributor
in your country.
Contact the Authorized Distributor
in your country.
Contact the Authorized Distributor
in your country.
Install and adjust the flow.
diagram 3
diagram 7
DIMENSÕES: veja página 6.
INSTALAÇÃO: veja páginas 7 a 11.
MANUTENÇÃO - veja página 13.
CONTEÚDO DA EMBALAGEM:
00474106: 1 torneira, 1 RRV (registro regulador de vazão), 1 chave para RRV, 1 caixa
de pilhas, 4 pilhas alcalinas tamanho AA, 1 chave sextavada 2,5 mm, 1 flexível, 1
adesivo orientativo e 1 manual de instalação.
00474206: 1 torneira, 1 RRV (registro regulador de vazão), 1 chave para RRV, 1 fonte
chaveada 12 V, 1 chave sextavada 2,5 mm, 1 flexível, 1 adesivo orientativo e 1 manual de
instalação.
ADESIVO ORIENTATIVO: cole-o na parede próximo ao produto.
PEÇAS DE REPOSIÇÃO E COMPONENTES: veja página 12. Poderá ser adquirido na
Assistência Técnica Docol. Dúvidas ligue 0800 474 333 ou
CONSERVAÇÃO E LIMPEZA: Deve ser usado apenas flanela, água e sabão neutro, pelo
menos uma vez por semana. Eventualmente pode ser aplicada cera automotiva a base de
silicone. Não use produtos abrasivos.
COMPOSIÇÃO DO PRODUTO: ligas de cobre, elastômeros, plástico de engenharia, aço
inoxidável e componentes eletrônicos.
GARANTIA: veja na página 16.
Para o melhor desempenho do sistema hidráulico, recomendamos seguir projeto realizado
por profissional credenciado ao CREA e seguir as normas ABNT, bem como nosso manual
de instalação.
PORTUGUÊS
3