the code to be a lot easier and reduces the flexibility when
code changing. The wire coinciding with a key which does
not appear in the set code need not be run, e.g. if the set
code is 3642 then the wires corresponding to keys 1 & 5
need not be used. The barrier strip numbering corresponds
with the keypad number, i.e. barrier strip terminal 1 controls
key 1 etc. Wires between strip numbers 7, 8 & 9 MUST be
connected.
4. OPERATION
On first connecting power, the system will be 'OFF'. Upon
entry of the correct combination (code), the code accept
LED (marked 'ON') will illuminate. After approximately 10
seconds, Output 1 and Output 1 LED on the CM6 Master
Unit will turn on. After approximately another 10 seconds
Output 2 and Output 2 LED will turn on. This sequence will
continue until all connected outputs have latched on. During
the turn-on sequence no 'OFF' code will be accepted.
After entry of the first correct digit of a code the rest of the
code must be entered within 5 seconds or the code will be
rejected. If an incorrect code is entered then wait about 10
seconds before trying again.
Once the 'ON' cycle has been completed, entry of the
correct code will start the turn-off sequence i.e. turn-on in
reverse.
Similarly to the 'ON' sequence the 'OFF' sequence will not
accept an 'ON' code until the system has completed its cycle.
If there is a loss of power the system will reset to 'OFF'.
5 TROUBLESHOOTING
OFF or ON LED lit Wrong code or link Check code & allow
but does not change cut on keypad PCB 20 secs between
tries on entry of code Some items of equipment that are
fitted with combined circuit breaker and ON/OFF switches
do not reliably turn on remotely i.e. when the item is left
turned on and the supply is connected. There is no solution
to this problem apart from removing the offending circuit
breaker; this is not recommended.
Note: These instructions apply to the installation and use of
the CR6 remote keypad unit.
Please read the full "Instructions for Use" of the Master
Switcher unit CM6 for full details of the complete switching
system.
EMO Systems, Canford Audio Plc Crowther Road Washington,Tyne & Wear, NE38 0BW. UK
by Canford
TECHNICAL DATA SHEET
For further information or servicing please contact your local
EMO Dealer.
Our Policy is one of continuous development: all
specifications and design details are subject to change
without notice.
emosystems.co.uk
02-475 v2