Dodge Quantis MSM Manuale di istruzioni - Pagina 16

Sfoglia online o scarica il pdf Manuale di istruzioni per Apparecchiature industriali Dodge Quantis MSM. Dodge Quantis MSM 16.

Dodge Quantis MSM Manuale di istruzioni
Dodge Industrial, Inc.
1061 Holland Road
Simpsonville, SC 29681
+1 864 297 4800
© DODGE INDUSTRIAL, INC.
AN RBC BEARINGS COMPANY
STANDARD
INTEGRAL
MOTOR
(LINE VOLTAGE
= L1, L2, L3)
INTEGRAL
BRAKE
MOTOR
(NO VFD OR
SOFT START)
INTEGRAL
BRAKE
MOTOR
WITH VFD OR
SOFT START
*BRAKE CAN NOT
BE POWERED
FROM MOTOR
TERMINAL BLOCK
ADD AUXILIARY SWITCH
FAST RESPONSE
BETWEEN B3 AND B5 TO
BRAKING:
BE OPEN FOR BRAKING
BRAKES ARE ELECTROMAGNETICALLY RELEASED;
SPRING SET
NOTE: FOR POSITIONING APPLICATIONS AN ADDITIONAL FAST RESPONSE
KIT IS AVAILABLE; ORDER DODGE PART NUMBER 031389 AND FOLLOW
WIRING INSTRUCTIONS THAT COME WITH THE KIT.
Figure 8 – Wiring Diagram for Dual Voltage/Single Speed Integral Motor
LOW VOLTAGE
230V
4
5
6
7
8
9
1
2
3
L1
L2
L3
4
5
6
7
8
9
1
2
3
L1
L2
L3
B1
B2
B3
B5
INSULATE B4
4
5
6
7
8
9
1
2
3
L1
L2
L3
S1
S2
*SEPARATE
SINGLE
PHASE
B1
B2
LINE TO
BRAKE
B3
B5
INSULATE B4
ADD AUXILIARY SWITCH
BETWEEN B1 AND B5 TO
BE OPEN FOR BRAKING
HIGH VOLTAGE
460V
4
5
6
7
8
9
1
2
3
L1
L2
L3
4
5
6
7
8
9
1
2
3
L1
L2
L3
B1
B2
B5
INSULATE B3
INSULATE B4
4
5
6
7
8
9
1
2
3
L1
L2
L3
S1
S2
*SEPARATE
SINGLE
PHASE
B1
B2
LINE TO
BRAKE
B5
INSULATE B3
INSULATE B4
*1617-0222*
All Rights Reserved. Printed in USA.
MN1617 02/22