DOEPEFER A-157-2 Manuale - Pagina 2
Sfoglia online o scarica il pdf Manuale per Apparecchiature musicali DOEPEFER A-157-2. DOEPEFER A-157-2 4. Trigger-sequenzer
Trigger-Sequenzer A-157-2/3
3. A-157-3 Control Input Module
The Control-Input Module A-157-3 is used to control the
sequencers run functions (start / stop / reset / clock). You
can either control them manually using the push buttons, or
by applying external signals of ≥ +3 Volts, resp. a clock
signal.
2
System A-100
3.1. Control keys / inputs
Start
Hitting the key (or routing a positive pulse into the respective
jack) will get the sequencer going from the current step
position.
Stop
Hitting the key (or routing a positive pulse into the respective
jack) will stop the sequencer at the current step position.
Reset
With the next incoming clock pulse, a key hit (or routing a
positive pulse into the respective jack) will start thesequence
at step #1.
Clock
Each time you are hitting the key (or routing a positive pulse
into the respective jack), the sequencer will advance to the
next step.
A steady clock signal (pulsewave) is used to drive the
sequencer at a steady pace.
Func. 1-4
(not implemented yet)
DOEPFER