3. Controls
1 Freq.
With this control you adjust the Cut-Off Frequency f
above which the filter attenuates all frequencies. At 10,
the filter is fully open. The more you turn down this
control, the more the high frequencies are filtered.
The sound becomes mellower and less bright (see
Fig. 1) until at 0 the filter is completely shut, and there
will be no output signal at all.
CV
Out
f c
Freq.
Fig. 1: White noise put through a low pass filter.
System A - 100
,
c
Out
f c
Freq.
2 CV 2
3 CV 3
For voltage control or modulation of the cut-off fre-
quency, use these CV inputs " and/or § (see Fig. 1).
Use attenuators 2 and/or 3 to adjust the control
voltage level.
4 Lev.
Use this attenuator to control the amount of signal
entering the filter input $.
H
If the filter's output distorts, turn this control
down, unless you deliberately want the
sound as a special effect.
5 Res.
With this control you adjust the filter's resonance
(emphasis) - the parameter which emphasises the
frequencies around the cut-off point f
p.4).
Close to its maximum setting, the filter becomes so
resonant that it goes into self-oscillation, and starts
behaving like a sine wave. You can take advantage
of this effect, and use the VCF as an additional oscilla-
tor.