Doepke Dupline DSU 2U Istuzioni operative - Pagina 6

Sfoglia online o scarica il pdf Istuzioni operative per Convertitore multimediale Doepke Dupline DSU 2U. Doepke Dupline DSU 2U 8. Signal converter 2-way binary input for ac/dc

Doepke
Terminal
D-
Dupline signal conductor - (Dupline-)
D-
Dupline signal conductor - (Dupline-)
NC
Spare
Connections between the Dupline signal and earth potential will cause malfunctions and
are not permissible. In addition, check for the correct polarity of the Dupline signal.
In order to meet the requirements for protective low voltage, VDE0100, Part 410, should
be observed and put into practice during installation. For reasons of safety and space
requirements, mains cables may not be routed through the same installation box.
In cases of mixed operation with AC voltage at one input and DC voltage at the other,
the above requirements are not fulfilled.

10. Indicators

Indicator
Green "BUS OK"
LED

11. Technical Data

Dupline
Input channels 2 input signals (E1/E2)
Output channels None
Inputs
DC voltage
AC voltage (50 Hz)
Operating Voltage
Rated operating voltage Not required (supplied by Dupline signal line)
Terminals
Control terminals
6
Description
Dupline bus:
Off - bus fault / On - bus OK
Current input
Type opto-decoupled, with rectification
Voltage
Current input
Line length
Voltage
Current input
Line length
Type 2-pole plug terminals (fitted)
Contact area
Terminal
Description
Min.
20 V
20 V
0.4 mm ∅
3931196/04/08/E
Description
Brown
Input Signal 2 (E2)
Brown
Input Signal 2 (E2)
Typ.
100 µA
15 mA
Max.
500 µA
300 V
100 m
250 V
50 m
0.8 mm²