CYP PU-44XL-KIT Manuale operativo - Pagina 9
Sfoglia online o scarica il pdf Manuale operativo per Commutatore a matrice CYP PU-44XL-KIT. CYP PU-44XL-KIT 20. Express installation kit - 4 x 4 hdbaset lite matrix with pu-514l-rx receivers
6.2 Rear Panel
IR OUT
IR IN
1
2
3
4
1
RS-232: Connect to a PC or control system with D-Sub 9-pin cable for
RS-232 control.
2
SERVICE: Manufacturer use only.
3
CONTROL: Connect to an active network for Telnet/Web GUI control
(refer to Section 6.8 for details).
Warning: Please do not connect this port directly to the PC/Laptop
as the Telnet function will not work.
4
ALL IR OUT: Connect to the IR blaster for IR signal transmission of the
source or display equipment. Place the IR blaster in direct line-of-sight
of the equipment to be controlled.
ALL IR IN: Connect to the IR extender for IR signal reception of the remote
control of this device or the source and display equipment. Ensure that
remote being used is within the direct line-of-sight of the IR extender.
5
IR IN 1~4: Connect the IR extenders for IR signal reception. Ensure
that the remote being used is within the direct line-of-sight of the IR
extender.
IR OUT 1~4: Connect the IR blasters for IR signal transmission. Place the
IR blaster in direct line-of-sight of the equipment to be controlled.
6
CAT5e/6/7 OUT A – D: Connect these CAT outputs to the CAT input port
of the receiver units with a single CAT5e/6/7 cable for HDMI Audio/Video
and IR control signal transmission.
7
HDMI IN 1~4: Connect to the HDMI input source devices such as a
DVD player or a Set-top Box with HDMI cable or DVI to HDMI cable.
8
DC24V: Connect the 24 V DC power supply to the unit and plug the
adaptor into an AC outlet.
5
ALL
1
A
2
B
CAT5e/6 OUT
CAT5e/6 OUT
IR OUT
IR OUT
IR OUT
IR IN
IR IN
IR IN
6
HDMI IN
1
2
3
4
7
5
3
C
4
D
GND
GND
2
1
CAT5e/6 OUT
CAT5e/6 OUT
4
3
V+
+
V
GND
IR OUT
IR OUT
IR IN
IR IN
DC 24V
6
8
9