To do this remove cage from machine and hold upside down. Look for gaps between ball and
washer. Change the float cage and ball should either become distorted. Gaps will allow water
through to the vacuum motor.
Spits of water coming from the exhaust vent located at the rear of the SENSEI is a tell-tale sign of
this problem. Should this happen, stop the machine, run the vacuum motor with recovery tank
lid off and replace the float cage if necessary. We always recommend the use of Ashbys Supreme
Defoamer in recovery tank.
Polyethylene body of the SENSEI can be cleaned with a damp cloth using soapy water – avoid
electrical components and ALWAYS UNPLUG THE MACHINE FIRST.
Finally for best results & a new appearance, clean with a silicone blended finishing product such
as a Dashboard Renovator.
Servicing should be every 6 months, or as required at Ashbys premises. It is usually false
economy to run an un-serviced machine beyond this time. Include in the service hoses, hand tool
& wand.
Flow control knob should never be screwed in tightly as this can strip internal thread. Screw in
only until full flow is achieved. Do not over tighten.
The Ashbys twin jet stainless steel wand has filters which should be cleaned occasionally. These
can be removed by unscrewing the jet restraining nut, removing jet, behind which is the filter.
Clean this using a nail brush.