DOL 26SCR Series Manuale tecnico per l'utente - Pagina 2
Sfoglia online o scarica il pdf Manuale tecnico per l'utente per Accessories DOL 26SCR Series. DOL 26SCR Series 4. Capacitive sensor
1 Product description
DOL 26 is a capacitive sensor for detection of loose and solid materials.
SCR output versions are available in 2-wire versions.
DOL 26SCR Serial is suitable for serial connection of sensors on the same load.
The products are suitable together with contactors, relays, PLC's and similar within the agricultural and indus-
trial sectors. DOL 26 is immune to EMI, short circuits and any overload. The mechanical design makes DOL 26
ideal for integration into applications with limited space. The full-return option is especially suited for feeding
pans. Very low power consumption in off state – enables possibility for sensors working in parallel on the same
contactor. Unique possibility for controlling cross auger systems.
2 Mounting guide
Smooth version mounted
within a PG 21 gland
Threaded version mounted with M18 nut.
3 Installation guide
Installation, servicing and troubleshooting of all electrical equipment must be carried out by quali-
fied personnel in compliance with the applicable national and international standard EN 60204-1
and any other EU standards that are applicable in Europe.
DOL 26SCR
LED indication
RED OFF
RED slow flashing
RED double flashing
RED ON
2
Mounting restrictions for non-flush (side sensi-
tive version)
DOL 26SCR:
Connect the sensor in series with the load. The polarity is unimportant.
The sensor is protected against overload and short circuit. If the output cur-
rent exceeds the nominal output current, the output function is switched off.
Remove the short circuit or choose a smaller load to remove the error. The
current limitation error is indicated on the sensor by double flashes followed
by a pause.
Sensor load error (overcurrent protection is active)
www.dol-sensors.com
DOL 26 SCR seriel status
Sensor output is OFF
Sensor delay is active
MaxRunTimer is active (optional)
Sensor output is ON
Technical User Guide
DOL 26SCR Serial