CYP Suprex SPX-7400 Series Manuale operativo - Pagina 11

Sfoglia online o scarica il pdf Manuale operativo per Estensore CYP Suprex SPX-7400 Series. CYP Suprex SPX-7400 Series 18. Reader extender - fiber optic interface

CYP Suprex SPX-7400 Series Manuale operativo
Cypress Suprex® F.O. Series - Door Strike and LED I/O
The Cypress
SPX-7400 provides additional data channels to support access control hardware such as door strikes,
tamper
alarms, request to exit status, etc. These signals are sent to and from the Remote and Central units without
"
the need to
run additional wiring."
The accessory control I/O use active low inputs. When the inputs are floating (nothing connected) the
associated output will be set to a high level. When the input is set to 0Volts (Ground) the input will
activate its associated output. All Accessory outputs are Open Collector type and will switch to Ground
"
when activated.
Each input will have an associated output. See the following pages for a diagram of each I/O pair.Inputs can be tested by
making a jumper connection to ground and monitoring the associated output.
Jumper to ground to test
"
Suprex® Fiber Optic
Ground
LED In
Input
Suprex® Fiber Optic
LED Out
Output
Central
Red arrow denotes direction of command signal
Remote