DOLD VARIMETER IMD RN 5897/011 Manuale - Pagina 9
Sfoglia online o scarica il pdf Manuale per Strumenti di misura DOLD VARIMETER IMD RN 5897/011. DOLD VARIMETER IMD RN 5897/011 17. Insulation monitor
Technical Data
EMC
Electrostatic discharge (ESD): 8 kV (air)
HF irradiation:
80 MHz ... 1 GHz:
1 GHz ... 2.7 GHz:
Fast transients:
Surge voltage
between
wires for power supply:
Between wire and ground:
HF-wire guided:
Interference suppression:
Degree of protection
Housing:
Terminals:
Housing:
Vibration resistance:
Shock resistance:
Climate resistance:
Terminal designation:
Wire connection
Cross section:
Stripping length:
Wire fixing:
Wire connection
Bus
pluggable
cage-clamp terminal (PC):
Insulation of wires or
sleeve length:
Fixing torque:
Mounting:
Mounting position:
Weight:
Dimensions
Width x height x depth:
IEC/EN 61326-2-4
IEC/EN 61000-4-2
20 V / m
IEC/EN 61000-4-3
10 V / m
IEC/EN 61000-4-3
2 kV
IEC/EN 61000-4-4
1 kV
IEC/EN 61000-4-5
2 kV
IEC/EN 61000-4-5
20 V
IEC/EN 61000-4-6
Limit value classe B
EN 55011
IP 30
IEC/EN 60529
IP 20
IEC/EN 60529
Thermpolastic with V0 behaviour
according to UL subject 94
Amplitude 0.35 mm,
Frequency 10 ... 55 Hz, IEC/EN 60068-2-6
Amplitude ± 1mm,
Frequency 2 ... 13.2 Hz, 13.2 ... 100 Hz,
acceleration ± 0.7 gn IEC/EN 60068-2-6
10 gn / 11 ms, 3 pulses IEC/EN 60068-2-27
30 / 060 / 04
IEC/EN 60068-1
EN 50005
DIN 46228-1/-2/-3/-4
0.5 ... 4 mm² (AWG 20 - 10) solid or
0.5 ... 4 mm² (AWG 20 - 10)
stranded wire without ferrules
0.5 ... 2.5 mm² (AWG 20 - 10)
stranded wire with ferrules
6.5 mm
Cross-head screw / M3 box terminals
0.14 ... 0.5 mm
solid or
2
0.14 ... 0.25 mm
stranded ferruled
2
7 mm
0.5 Nm
DIN rail
IEC/EN 60715
Vertical
(air flow trough ventilation slots
must be ensured)
Approx. 205 g
52.2 x 90 x 71 mm
Classification to DIN EN 50155
Vibration and
shock resistance:
Service temperature classes: OT1 compliant
Protective coating of the PCB: No
Standard Types
RN 5897.12/011
Article number:
• Auxiliary voltage:
RN 5897.12/011
Article number:
• Auxiliary voltage:
• Outputs:
• Setting range Pre-Alarm:
• Setting range Pre-Alarm:
• Setting range Alarm:
• Setting range Alarm:
• With Modbus RTU interface
• Trigger output for insulation fault locating system
• With connection facility of a coupling device RL 5898 or RP 5898
• Adjustable line capacitance
• Energized or de-energized on trip
• Selection of type of network
• Width:
Ordering Example for variants
RN 5897 .12 /011 /61 AC/DC 24 ... 60 V 1 kΩ - 250 kΩ 20 kΩ - 2 MΩ
9
Category 1, Class B
IEC/EN 61373
AC/DC 24 ... 60 V
0069283
AC/DC 24 ... 60 V
AC/DC 100 ... 230 V
0069284
AC/DC 100 ... 230 V
1 changeover contact for pre-warning
1 changeover contact for alarm
20 kΩ ... 2 MΩ (via rotary switch)
1 kΩ ... 2 MΩ (via Modbus)
1 kΩ ... 250 kΩ (via rotary switch)
1 kΩ ... 2000 kΩ (via Modbus)
52.5 mm
Setting range Pre-warning
Setting range alarm
Auxiliary voltage
UL approval
Variant, if required
Contacts
Type
30.06.23 de / 752A