Technical Data
Phase / motor
voltage L1/L2/L3:
Nominal frequency:
Nominal motor power P
N
at 400 V:
Switching frequency
, 5 s, ϑ
at 3 x I
= 45°C:
N
U
max. permissable braking current: 50 A
Min. motor power:
Start torque:
Ramp time:
Braking time:
Braking delay:
Braking voltage:
Start delay:
Auxiliary voltage U
H
model DC 24 V:
Power consumption:
Residual ripple max.:
Max. semiconductor fuse:
Inputs
Control input X1, X2:
Input P2 / P3 for bi-metal contact
Switching current:
Switch voltage:
Input P1 / P2 for PTC-sensor
Thermal sensor:
Number of sensors:
Response value:
Measuring voltage:
Monitoring Output
Contacts:
Thermal continous current I
: 4 A
th
Switching capacity
to AC 15
NO contact:
Electrical life:
to AC 15 at 3 A,
AC 230 V:
Short circuit strength
max. fuse rating:
General Data
Temperature range
Operation:
Storage:
Altitude:
Clearance and creepage
distances
Rated impulse voltage /
pollution degree
Control voltage to auxiliary
voltage, motor voltage:
Auxiliary voltage to
motor voltage:
motor voltage to heat sink:
EMC
Electrostatic discharge:
HF-irradiation
80 MHz ... 1 GHz:
1 GHz ... 2,5 GHz:
2,5 GHz ... 6 GHz:
Fast transients:
Surge voltages
between
wire for power supply:
between wire and ground:
HF wire guided:
3 AC 200 V -10 % ... 480 V + 10 %
50 / 60 Hz
11 kW
20 / h
eff.
0.1 P
N
20 ... 80 %
1 ... 20 s
Max. 20 s
750 ms
DC 10 ... 90 V
250 ms
A1/A2, DC 24 V, + 10 %, - 15 %
2 W
5 %
6600 A
s
2
DC 24 V / 2.5 mA / edge triggered
DC 1 mA
DC 5 V
According to DIN 44081
1 ... 6 in series
3 kΩ
Max. DC 5V
3 x 1 NO contacts
3 A / 230 V
IEC/EN 60947-5-1
2 x 10
switch. cycl.
IEC/EN 60947-5-1
5
4 A gG / gL
IEC/EN 60947-5-1
0 ... + 45 °C
- 25 ... + 75 °C
< 2000 m
4 kV / 2
IEC 60664-1
4 kV / 2
IEC 60664-1
6 kV / 2
IEC 60664-1
8 kV (air)
IEC/EN 61000-4-2
10 V / m
IEC/EN 61000-4-3
3 V / m
IEC/EN 61000-4-3
1 V / m
IEC/EN 61000-4-3
2 kV
IEC/EN 61000-4-4
1 kV
IEC/EN 61000-4-5
2 kV
IEC/EN 61000-4-5
10 V
IEC/EN 61000-4-6
Technical Data
Interference emission
Wire guided:
Radio irradiation:
Degree of protection:
Housing:
Terminals:
Vibration resistance
Frequency range:
Amplitude:
Acceleration:
Climate resistance:
Wire connection
Load terminals:
Control terminals:
Stripping length:
Wire fixing
Load terminals:
Fixing torque:
Control terminals:
Fixing torque:
Mounting:
Weight:
Dimensions
Width x height x depth:
Standard Type
BL 9028.03 3 AC 200 ... 480 V 50/60 Hz U
Article number:
• Nominal motor power
at 3 AC 400 V:
• Control input X1, X2:
• Width:
Variant
BL 9028.03/_1_:
Ordering Example
BL 9028. 03/_ _ _
3 AC 200...480 V
3
Limit value class A
IEC/EN 60947-4-2
Limit value class A
IEC/EN 60947-4-2
The device is designed for the usage
under industrial conditions (Class A,
EN 55011). When connected to a
low voltage public system (Class B,
EN 55011) radio interference can be
generated. To avoid this, appropriate
measures have to be taken.
IP 40
IEC/EN 60529
IP 20
IEC/EN 60529
IEC/EN 60068-2-6
10 ... 100 Hz
0.35mm peak to peak up to 54 Hz
Above 54 Hz constant acceleration 4 g
0 / 045 / 04
IEC/EN 60068-1
1 x 10 mm
solid
2
1 x 6 mm
stranded ferruled
2
1 x 4 mm
solid or
2
1 x 2.5 mm
stranded ferruled (isolated) or
2
2 x 1.5 mm
2
stranded ferruled (isolated)
DIN 46228-1/-2/-3/-4 or
2 x 2.5 mm
2
stranded ferruled
DIN 46228-1/-2/-3
10 mm
Plus-minus terminal screws M4
box terminals with wire protection
1.2 Nm
Plus-minus terminal screws M3.5
box terminals with wire protection
0.8 Nm
DIN rail mounting
IEC/EN 60715
1135 g
112.5 x 85 x 121 mm
DC 24 V 11 kW
H
0068352
11 kW
DC 24 V
112.5 mm
Motor protection with bi-metal contact or
PTC thermal sensor
50/60 Hz U
DC 24 V 11 kW
H
Nom. motor power
at 3 AC 400 V
Aux./Control voltage
Nom. frequency
Phase / motor voltage
Variant
0 = Standard
0 = Standard
1 = Input P1/P2/P3
for motor temp.
monitoring
0 = With standstill
detection
Contacts
Type
11.01.21 en / 335A