Cloud 50 Manuale di installazione e funzionamento - Pagina 12
Sfoglia online o scarica il pdf Manuale di installazione e funzionamento per Amplificatore Cloud 50. Cloud 50 13. 4 zone integrated mixer amplifier
Anche per Cloud 50: Manuale di installazione e funzionamento (14 pagine)

44/50: Installation and Operation Manual
31
Technical Specifications
Line inputs
Frequency Response
Distortion
Sensitivity
Input Gain Control
Input Impedance
Headroom
Noise
Equalisation
Microphone Inputs
Frequency Response
Distortion
Gain Range
Input Impedance
Common mode rejection
Headroom
Noise
Equalisation
Outputs
Auxiliary Outputs
Speaker Outputs
100V line output
70V line output
Protection
Cooling
32
General Specifications
Power input
Fuse rating
Fuse type
Dimensions
Weight
20Hz-20kHz ±0.5dB
<0.05% 20Hz -20kHz
195mV (-12dBu) to 2.0V (+8dBu)
20dB range
47kΩ
>20dB
-90dB A weighted (0dB gain)
HF: ±10dB/10kHz
LF: ±10dB/50Hz
100Hz / -3dB(filter) 20kHz ±0.5dB
<0.05% 20Hz-20kHz
0dB-60dB
>2kΩ (balanced)
>70dB 1kHz
>20dB
-128dB EIN 22Hz-22kHz (150Ω)
HF: ±10dB/5kHz
LF: ±10dB/100Hz
775mV (0dBu) unbalanced (RCA phono sockets)
50 watts rms/4Ω 35watts rms/8Ω via binding posts
100 volts balanced – 250Ω min load (optional module)
70 volts balanced – 125Ω min load (optional module)
VI Limiting, DC Offset, Thermal & switch-on delay
Three speed DC fan
230V ±5% (115V ±5% available)
230V – T3.15A
115V – T6.3A
20mm x 5mm class 3T 250V
482.60mm x 88.00mm(2U) x 300.00mm deep (+ con)
6.25kg net
11