Cloud Z8II Manuale d'installazione e d'uso - Pagina 17

Sfoglia online o scarica il pdf Manuale d'installazione e d'uso per Mixer musicale Cloud Z8II. Cloud Z8II 18. Venue mixer

16
27

EMC Considerations

The Cloud Z4 & Z8 fully conform to the relevant electromagnetic compatibility (EMC)
standards and are technically well behaved; you should experience no operational problems
and under normal circumstances, no special precautions need to be taken. If the unit is to be
used within close proximity to potential sources of HF disturbance such as high power
communications transmitters, radar stations and the like, the performance of the mixer may
be reduced; we suggest that the microphone cable screen be connected to the shell of the
XLR type connector and the line input leads are kept as short as possible.
28

Technical Specifications

Line inputs
Frequency Response
Distortion
Sensitivity
Input Gain Control
Input Impedance
Headroom
Noise
Equalisation
Microphone Inputs
Frequency Response
Distortion
Gain Range
Input Impedance
Phantom power
Headroom
Noise
Equalisation
Facility Input
Input Impedance
Sensitivity
Noise Gate
Outputs
Balanced Zone Outputs
Minimum load impedance
Maximum output level
29

General Specifications

Power input
Fuse rating
Fuse type
Dimensions
Weight
30/05/03 V8
20Hz-20kHz ±0.5dB
<0.05% 20Hz -20kHz
195mV (-12dBu) to 2.0V (+8dBu)
20dB range
47kΩ
>20dB
-90dB A weighted (0dB gain)
HF: ±10dB/10kHz
100Hz / -3dB(filter) 20kHz ±0.5dB
<0.05% 20Hz-20kHz
10dB-50dB
>2kΩ (balanced)
+15V (PCB jumper for on/off)
>20dB
-120dB EIN 22Hz-22kHz (150Ω)
HF: ±10dB/5kHz
10kΩ (balanced) pin 3(+) pin 4(-)
0dBu – 775mV
Ground pin 5 to open
775mV (0dBu) 3 pin 'Phoenix' type connector
600 ohms
+20dBu (7.75V)
230V ±10% 115V ±10% AC 40-60Hz
Z8: 230V – T125mA H
Z4: 230V – T100mA H
20mm x 5mm 250V
482.60mm x 132.50mm(3U) x 160.00mm deep
(+ connectors)
Z4 3.83 kg net
Z8 4.40 kg net
Z4
& Z8
: Installation and User Guide
II
II
LF: ±10dB/50Hz
LF: ±10dB/100Hz
115V – T250mA H
115V – T200mA H