Cloud CAS-16 Manuale d'installazione e d'uso - Pagina 11
Sfoglia online o scarica il pdf Manuale d'installazione e d'uso per Trasformatore Cloud CAS-16. Cloud CAS-16 12. Audio distribution sub-station and matrix
Technical Specifications
Frequency response
Input level
Input impedance
Line Inputs
Input gain range
Input level indicator
Input connector
Frequency response
High pass filter
Gain range
Global Input
Input impedance
CMR
Access contact
Nominal output level
Line Output
Channel 16
Minimum load
Nominal output level
Headphone Output
Optimum load impedance
via RH-8 or WP-8
Recommended headphones
Nominal output level
Speaker Output
via WP-8
Optimum load impedance
Power consumption
Width
Other
Height
Depth
Weight
Output
PSU
Weight
CAM-16
20 Hz – 20 kHz ±0.5 dB
-14 dBu (155 mV) to
+6 dBu (1.55 V)
47k ohms
20 dB
LED – illuminates above a
fixed threshold
2 x RCA phono jack (stereo)
20 Hz – 20 kHz ±1 dB
-3 dB @ 200 Hz – 18 dB/oct
(with in/out switch)
0 dB to 50 dB
5k ohms
>70 dB @ 1 kHz
Channel off/on by closing
contact
0 dBu (775 mV)
600 ohms
100 mW per channel with 32 ohm load
Cloud CP32
150 mW per channel with 8 ohm load
>8 ohms
25 VA with approved external
transformer
482.6 mm (19.0")
88.0 mm (3.50") – 2U
170.0 mm (6.70") + connectors
4.0 kg net
15 V AC 1.25 A 18.5 VA
0.52 kg net
CAM-16 / CAS-16 User Manual v1.0
CAS-16
32 ohms
20 VA with approved external
transformer
3.3 kg
11