Cloud BE-1 Series Manuale di installazione - Pagina 4
Sfoglia online o scarica il pdf Manuale di installazione per Unità di controllo Cloud BE-1 Series. Cloud BE-1 Series 4. Balanced line input modules

Connecting Multiple BE-1s
Multiple BE-1s may be "daisy-chained" together to provide input points at different locations in the same zone. Signals applied to
modules wired in this way will be summed together and fed to the DCM1 Line Input to which the "first" BE-1 in the chain (that
whose OUTPUT socket is connected directly to the DCM1). An internal gating circuit on each module automatically "disconnects"
any chained modules which are not in use, to minimise noise contribution. Chained modules will be treated as a single line input
at the DCM1.
Multiple BE-1s in the same zone may be daisy-chained by connecting the LINK RJ45 socket on the first BE-1 to the OUTPUT
socket on the second BE-1, and so on, as shown below.
Additional
input plates
Interconnecting BE-1 and LE-1 remote input modules
The Cloud LE-1 is an alternative range of optional remote line input modules, providing an unbalanced stereo line input on both
phono sockets and a 3.5 mm jack socket. BE-1 modules may be intermixed with LE-1s in a daisy-chain wiring arrangement in the
manner described for BE-1s alone, using the LE-1's OUTPUT and LINK connectors. All the modules on a chain will be treated as
a single line input at the DCM1.
Note that is not possible to intermix BE-1s with Cloud ME-1 remote microphone input modules in this manner.
DC Power
The BE-1 is powered from the DCM1's EXTENSION PORTs via the Cat 5 connection. The BE-1 consumes 24 mA of current from
the DCM1 power supply.
If there is any doubt regarding the DCM1's spare DC power capacity (as might be the case in a very large system with many CDR-1
remote controls, level restoration relays, etc.), please refer to the DCM1 Installation and User Guide (Appendix; PSU capacity) where
full details of the DCM1's PSU ratings can be found.
Should you have any questions concerning the installation and connection of the BE-1, please visit www.cloud.co.uk/resources,
where you will find additional technical information.
Cloud Electronics Limited
140 Staniforth Road, Sheffield, S9 3HF. England.
Telephone: +44 (0)114 244 7051 Fax: +44 (0)114 242
5462 Web: www.cloud.co.uk E-mail: [email protected]
4
BE-1 Series Installation Guide v2.0
BE-1
BE-1
LINK
OUTPUT
LINK
BE-1
Additional
input plates
LINK
BE-1
OUTPUT
LINK
OUTPUT
ZONE 1
BE-1
OUTPUT
LINK
OUTPUT
ZONE 2
Cloud Electronics USA
2065 Sidewinder Drive, Suite 200, Park City,
Utah 84060. United States of America.
Toll Free: 0855 810 0161
Web: www.cloudusa.pro E-mail: [email protected]
To DCM-1
Extension Ports
(one per zone).