Cloud CX335 Manuale di installazione e funzionamento - Pagina 13
Sfoglia online o scarica il pdf Manuale di installazione e funzionamento per Apparecchiature di registrazione Cloud CX335. Cloud CX335 15. Compressor-limiter
Anche per Cloud CX335: Manuale di installazione (16 pagine)
Page 12
6h
Gain Reduction Meter
A nine-segment LED bar graph meter continuously monitors the gain reduction applied by
the compressor and or limiter and even any remote control voltage over the range 0 to 30dB.
The amount of gain reduction shown is greatly affected by all of the front panel controls.
6i
Output Level Meters
These are nine segment LED bar graph level meters, that monitor the level of the two output
signals over the range -20dB to +12dB with reference to the 0dBu operating level. With
average stereo programme these will track together. Vastly differing levels will most likely be
a cable short or external system configuration fault.
7
Operation
The unit should be connected in line with the stereo signals to be processed either by
breaking the existing connection between mixer console and cross-over or amplifiers or via
suitable insert points on the master outputs of the console (if such exist).
Setting up the front panel controls is easiest if the peak limiter threshold is initially set to
maximum. This allows the compressor to be set up in isolation. The ratio setting depends
on how firmly the signal dynamics need controlling; commonly, higher ratios provide a higher
degree of control but also tend to be more audible in operation when high levels of gain
reduction are required. The integral soft-knee feature of the CX335 renders these effects far
less pronounced, but this factor should still be taken into consideration when setting up.
Although, with the CX335 a higher compression ratio may be used than that of conventional
compressors without compromising the sound quality.
Adjust the threshold control until the desired amount of gain reduction occurs. This is judged
partly by ear and partly by observing the gain reduction meter. In general, a maximum gain
reduction of between 6dB and 10dB will be adequate. When in the soft knee mode, you will
notice that the threshold control is rotated clockwise more than would normally be expected.
Set the gain control to give the required output level using the level meter to guide you.
Additional assistance can be obtained by toggling between bypass mode and normal
compressor operation, in both modes the optimum gain setting will give equal output levels
on the meter, but a slight increase in the 'music power' with the compressor operating. Avoid
running at very high output levels as this reduces the available amount of signal headroom
and could lead to distortion in extreme cases.
Once the gain is correct, set the peak limiter level control so that the limiter LED only lights
briefly on extreme signal peaks. Alternatively, set the peak limiter level to the desired
maximum output value and then adjust the compressor gain control to ensure minimum
limiter activity. One major use of the peak limit control is to prevent input distortion or
clipping on the following amplifiers. If only peak limiting is required then we suggest setting
the compressor ratio to greater than 1:20, the compressor threshold to at least 12dB lower
than the normal input level and using the soft-knee mode as opposed to using the peak
limiter alone.
The peak limiter has no separate on / off control, but turning the peak Level control fully
clockwise will prevent any unwanted limiter action. To effectively bypass the compressor
section turn the compressor threshold up to its maximum of +10dB (fully counter-clockwise)
15-07-02 V3
CX335: Installation and Operation Manual