TROUBLESHOOTING
FAULT
CAUSE
•
Fastener does
Fastener may be
not penetrate
too long
•
deep enough
Driving power may
be too low
•
Fastener bends
Hard and/or large
aggregate in
concrete
•
Rebar close to
surface of concrete
•
Hard surface (steel)
•
Base material is
High strength
spalling
concrete
•
Hard and/or large
aggregate in
concrete
•
Old concrete
•
Fastener does
Driving power too
not penetrate
low
•
surface
Application limit
exceeded (very
hard surface)
•
Unsuitable system
•
Fastener breaks
Driving power too
low
•
Application limit
exceeded (very
hard surface)
•
Wasted (unused)
The tool is not
cartridges
pressed fully
against the work
surface
POSSIBLE REMEDIES
•
Use shorter fastener if
permissible
•
Increase power setting
•
Use heavier cartridge
•
Use a more powerful
system
•
Use shorter fastener if
permissible
•
Use a fastener with a
higher application limit
•
Change to single
fasteners
•
Use an alternative
fastening system
•
Adjust the power setting
•
Use an alternative system
•
Use a shorter pin if
permissible
•
Use a lower power level
•
Use a higher power
setting or heavier
cartridge
•
Use fastener with higher
application limits
•
Switch to more powerful
system
•
Try higher power setting
or heavier cartridge
•
Use a shorter fastener if
permissible
•
Use fastener with higher
application limits
•
Switch to more powerful
system
•
Press the tool fully
against the work surface
before pulling the trigger
•
Do not press the tool
multiple times between
fastenings.
30
TROUBLESHOOTING
FAULT
CAUSE
•
Piston guide
The piston is
sticks
damaged
•
Remains of plastic
strip in magazine
•
Driving power too
high when driving
into steel
•
Firing the tool with
high power without
a fastener in place
•
The tool is dirty
•
Fastener is
Two fasteners are
jammed in the
jammed together in
magazine
the magazine
POSSIBLE REMEDIES
•
Unscrew the magazine
•
Unscrew the black
housing
•
Check the piston and
replace if necessary
•
Open the magazine and
remove the nail strip and
any plastic debris
•
Reduce driving power
•
Avoid firing without a
fastener in place
•
Clean the tool
•
Insert the tip of a
screwdriver through the
furthest forward slot in the
magazine and push the
nails out
31