6.
MODIFICATION
The transformer in this EG&G ORTEC 402A Power
Supply has a tap in each of the primary windings to per
mit operation with a nominal 100/200 V ac input. The tap
for one primary is a yellow wire and for the other primary
is a white wire. These leads are covered with shrinkable
tubing over the ends and are included in the bundle of
leads from the transformer.
To operate the 402A Power Supply from either a 100 or
200 V ac power source, use the following steps to change
the primary winding connections;
1. Remove the top cover from the 402A Power Supply.
2. Remove the two piug-in regulator boards.
3. Locate the unused yellow and white wires and
remove the shrinkable tubing from the wire ends.
4.
Disconnect the black wire from the 117/230 V ac
switch and connect the yellow wire to the switch terminal
in place of the black wire.
5.
Disconnect the black/white and red wires from the
117/230 V ac switch and connect the white wire to this
switch terminal.
6. Use shrinkable tubing or electrical insulation tape to
cover the bare end of the black wire.
7. Connect the black/white and red wires together and
wrap the ends with electrical insulating tape.
8. Return the two plug-in regulator boards and the top
cover to the 402A Power Supply.
The 402A is now wired for 100/200 V ac line operation
instead of 117/230 V ac. Ensure that the switch selects
the proper range before applying power to the unit.