Cytronix LSS05 Manuale d'uso - Pagina 15
Sfoglia online o scarica il pdf Manuale d'uso per Sensori di sicurezza Cytronix LSS05. Cytronix LSS05 17. Auto-calibrating line sensor
5V GND 01 02 03 04 05 Cal
6.1.2 Using the calibration signal
The calibration signal from the sensor connector can be used to perform exactly the
same function as the calibration push button. The calibration signal line requires user to
generate falling edges to set for appropriate mode. LSS05 detect how many falling edges to
set to appropriate mode.
• One falling edge pulse for calibration mode as shown in figure below. After the
falling edge pulse the sensor will start calibration.
• Two falling edges for setting the LSS05 into dark line mode. The 2 falling edges need
to be in range of 1.5 seconds.
Created by Cytron Technologies Sdn. Bhd. – All Rights Reserved
1.5s
ROBOT . HEAD to TOE
Product User's Manual – LSS05
15