amberroot 0B2 Manuale d'uso - Pagina 8
Sfoglia online o scarica il pdf Manuale d'uso per Caricabatterie amberroot 0B2. amberroot 0B2 17. Solar mppt charger for upgrading inverters
Note: Do not use a washer between the Battery lugs and the terminal [3]. Allow direct
contact of the lugs to the terminals to reduce resistance.
4.5 Inverter Connection
REhub is meant to add SAFE Solar PV to existing Inverters. The Mains input LIVE of the
Inverter is controlled by REhub. Disconnect the Mains to Inverter connection plug and
connect to the REhub Socket [7]. Connect MAINS input cable [6] to Mains Live input. The
rated Load current of the connected Inverter MUST be less than 100A. Keep the Inverter
in Away/ Off mode till you are ready for the Final Power UP
.
5 Screens and indications
REhub has a 16X 2 LCD screen and three LED indicators. The display scrolls through various
screens and is a useful indicator for details on what is happening with the charger. The LED
indicators give a quick status update.
5.1 Information provided on the LCD screen
5.1.1 Start-up screens
REhub MPPT
Amberroot Sys
Make sure that the correct battery system voltage is recognized (Example screen shows unit
connected to 24V battery system). If the unit is connected to 12V battery system, the last screen
must show the battery system voltage as 12V.
5.1.2 Display screens
The display scrolls through the screens shown above. Solar is Y if available. Mains is Y if available.
Mains to Inv is Y if the Mains input to the Inverter is ON. The + / - sign indicates that a counter is
running which will change the state from Y to N .
Solar Y Mains Y
Mains to Inv: Y +
The Battery status screen shows the Net Amps delivered to the batteries and the battery Voltage.
By default, the maximum +Ve current to the batteries is set to 18A. A negative value indicates that
the Load is higher than Solar, and the Amps shown in being drawn from the batteries. The Solar
output screen shows the Output Amps and the instantaneous Power generated. The external
temperature value is used for Temperature compensated battery charging. This value is shown only
of the external temperature sensor is connected to the unit.
The 'Energy' screen shows the Cumulative energy generated by Solar PV.
8
Model 0b2
12/24V – 40A
Battery
27.45V
+ 13.5 A
Solar Unit
12 kWhr
Ver 7.0
Ver:0x035 DB:24
SL # 0b200526
Solar Input
71 V
Int temp 36'C
Ext temp 28'C
Battery System
Voltage 24V
Solar
Output
96.07W
3.5 A
User Manual