d&b audiotechnik Ci60 Manuale - Pagina 5

Sfoglia online o scarica il pdf Manuale per Altoparlanti d&b audiotechnik Ci60. d&b audiotechnik Ci60 10. Flying bracket
Anche per d&b audiotechnik Ci60: Manuale (10 pagine), Istruzioni per il montaggio (11 pagine)

d&b audiotechnik Ci60 Manuale
1+
1-
2+
passive
2-
crossover
1+
1-
2+
2-
Fig. 2: Connector wiring
10
5
0
-5
-10
-15
-20
-25
-30
20
100
1k
Fig. 3: Frequency response correction with
HFA setting
Ci45/Ci60/Ci90 Manual

Connections

Since November 2004 the Ci45/Ci60/Ci90 cabinets are fitted with two
NL4 connectors. All pins of both connectors are wired in parallel using
the pin assignments 1+/1–. Using one connector as the input, the
second connector allows for direct connection to additional
loudspeakers.
Installation loudspeakers with the weather resistant option are supplied
with a fixed cable (PG).
Cable type:
Standard length: 5.5 m (18 ft)
Pin equivalents of NL4 connectors and fixed cable option (PG) are listed
in the table below.
NL4
PG

Operation with D6 or D12

Select the controller setup Ci45, Ci60 or Ci90.
Within the D12 amplifier these are available in "Dual Channel" and
"Mix TOP/SUB" mode.
Up to a total of two Ci45/Ci60/Ci90 loudspeakers can be driven by
each D6 or D12 amplifier channel.
In applications with low continuous levels and low ambient temperatures
up to three cabinets can be connected to a D12 channel.
Controller settings
For acoustic adjustment the functions CUT, HFA and CPL can be
selected.
CUT circuit
Set to CUT, the Ci45/Ci60/Ci90 low frequency level is reduced. The
loudspeaker is now configured for use with the Ci-SUB, Q-SUB or d&b
C-Series subwoofers.
HFA circuit
In HFA mode (High Frequency Attenuation), the HF response of the
system is rolled off. The HFA circuit provides a natural, balanced
frequency response when a unit is placed close to listeners in near field
or delay use.
High frequency attenuation begins gradually at 1 kHz, dropping by
approximately 3 dB at 10 kHz. This roll-off mimics the decline in
frequency response experienced when listening to a system from a
distance in a typically reverberant room or auditorium.
10k
20k
(9.2 EN)
H-07-RN-F 2 x 2.5 mm2/AWG 13
1+
1–
Brown (+)
Blue (–)
2+
2–
Page 5 of 10