WARNING: This wire MUST be fused with a 15 amp fuse in the Master
Controller's in-line fuse-holder.
Wiring to Searchlight
The RCL-50B searchlight is supplied with a 12-foot integral wire harness. This wire
harness is cut to this length specifically to allow for a voltage drop. Shortening the
harness will decrease the life of the bulbs. Any extra length of wire harness should be
loosely coiled in a convenient place. For best performance, the controller should be
attached to the end of the 12' searchlight wire harness. If you must lengthen the wire
harness, use heavy duty wire to minimize the voltage drop. This is especially important
for the yellow lamp power and green lamp ground wires.
Following the wiring scheme shown in Table 1 use the supplied butt connectors to
connect the master controller to the searchlight.
Wiring to Point Pad™
The RG-59 coax cable is supplied without the "F" connectors attached for ease of
routing. After the coax has been routed, strip the insulation and crimp the "F" connectors
in place. Screw the "F" connectors to the master controller and the Point Pad™.
Wiring to Power Supply
The power source must be a fused 12 VDC, 5-amp supply or 24 VDC, 3-amp supply.
Following the wiring scheme in Table 1, use the supplied butt connectors to connect the
Master Controller to the power source. Refer to Table 2 for proper wire size for
connection of the input power lines.
NOTE: As per the wiring scheme, the orange wire is connected to the positive terminal
and the blue wire is connected to the negative terminal of the power source.
CAUTION: observe polarities when attaching wires!
Wire Size
#8 AWG
#10 AWG
#12 AWG
Function
The URC-102 Master Controller is designed to perform up to six different duties on
searchlights, winches, and other electrical devices. The Master Controller provides
optimum voltage to ensure brightest performance and long lamp life, regardless of boat
system voltage fluctuations. The Master Controller is compatible with devices requiring
12 VDC or 24 VDC operation.
Y1-03-0141D
Maximum Cable Length
12v System
25 ft.
15 ft.
10 ft.
Table 2
24v System
100 ft.
60 ft.
40 ft.