SECTION 5- CARE AND MAINTENANCE
5.1
General care
The RCL-600A is relatively maintenance free. Clean the exterior of the light with a mild detergent and water if
desired. Rotate the light left, then right and up then down periodically to keep motors and turning surfaces clean
and operational.
WARNING: DO NOT rotate the light manually. This will strip the gear rack.
5.2
Bulb Replacement
A 150W xenon short arc lamp is provided with your RCL-600A. If it should need replacement, it can be ordered
through an ACR dealer or through ACR Electronics. The part number is P/N 6007.
CAUTION: Failure to follow replacement instructions carefully can result in damage to bulb and/or lights. All
part sales are final.
To replace the lamps, follow these steps:
WARNING: Turn OFF the power switch when installing lamp.
WARNING: Do NOT touch glass or parabolic reflectors with fingers or tools! Use cloth gloves.
1. Disconnect unit from power source and allow cooling.
2. Remove four screws holding front frame and glass with provided 6mm hex wrench.
3. Loosen mounting collar of lamp by turning collar counter clockwise. Unhook wire from opposite end of lamp. Pull
lamp out of mounting collar. Installation is done in reverse order.
4. Replace front frame and glass and install the four retaining screws. Be sure gasket is properly lubricated and
securely in place.
5. Reconnect unit to power source.
CAUTION: If you handle the xenon lamp with dirty hands, wipe off the stain on the glass with alcohol.
Y1-03-0139H
MOUNTING COLLAR
Figure 7
9