Ambient Weather WS-MOF0831-CTH Manuale d'uso - Pagina 3
Sfoglia online o scarica il pdf Manuale d'uso per Stazione meteorologica Ambient Weather WS-MOF0831-CTH. Ambient Weather WS-MOF0831-CTH 5.
It is not uncommon to have low humidity reading during cold weather when indoor air is heater. Air
conditioning also removes moisture from the air. The optimum levels are 45% to 50% during
heating and cooling seasons. Low humidity can cause health problems and can be hard on wood
furnishings. High humidity can cause mold or mildew to grow.
3.2 Hygrometer Accuracy
Humidity measurement is among the more difficult problems in basic meteorology. Accuracy is
difficult to achieve and are subject to drift, so need regular recalibration.
A further difficulty is that most hygrometers sense relative humidity rather than the absolute amount
of water present, but relative humidity is a function of both temperature and absolute moisture content,
so small temperature variations within the air in a test chamber will translate into relative humidity
variations.
4. Dial Thermometer
Figure 2
The dial thermometer uses a bimetallic strip wrapped into a coil. One end of the coil is fixed to the
housing of the device and the other drives an indicating needle. The principle behind a bimetallic strip
thermometer relies on the fact that different metals expand at different rates as they warm up. By
bonding two different metals together, the coil bends, causing the needle to move. Bimetallic
thermometers are not as accurate as bulb (mercury or red spirit) thermometers. The dial thermometer
should require no calibration.
Version 1.0
©Copyright 2015, Ambient LLC. All Rights Reserved.
Page 3