preliminary notes
please note:
gas connection RC 1/2"
}
(ISO 7/1-RC 1/2)
A nipple 1/2" (ISO 228-1-G 1/2A) is
supplied for those countries where it is
required.
The fitting of the appliance should only be
carried out by registered Corgi gas fitter.
The type of gas in the country for which the
appliance is equipped is stated on the data
plate.
This appliance must be installed by an
authorized person.
This appliance shall be installed in
accordance with the manufacturers
installation instructions, local gas fitting
regulations, municipal building codes,
electrical wiring regulations, AS5601 /
AG601 - Gas installations and relevant
statutory regulations.'
The appliance is not suitable for connection
with a flexible hose.
There are two ways to carry out the
connection to the main gas line:
A. The hotplate can be connected with rigid
pipe as specified in AS5601 table 3.1.
B. The hotplate can be connected with a
Flexible Hose, which complies with
AS/NZS 1869 (AGA Approved), 10 mm
ID, class B or D, no more than 1.2 m long
and in accordance with AS5601. Ensure
that the Hose does not contact the hot
surfaces of the hotplate, oven,
dishwasher or other appliance that may
be installed underneath or next to the
hotplate.
building-in
preliminary notes
warning:
please note:
electrical connection
warning:
}
Ensure that the hose assembly is restrained
from accidental contact with the flue or flue
outlet of an underbench oven. The hose
should not be subjected to abrasion,
kinking or permanent deformation and
should be able to be inspected along its
entire length. Unions compatible with the
hose fittings must be used and connections
tested for gas leaks. The supply connection
point shall be accessible with the appliance
installed.
Before operating the appliance, check the
gas connections with a soap/water mix for
any leaks.
240 V a.c., 50 Hz - 0.6 Watt
This hotplate is supplied with a plug &
cord. Simply plug into a 3 pin household
socket outlet which is properly earthed.
In order to avoid hazard, any electrical work
performed on this equipment or its
associated wiring, should only be done by
persons authorised by the supplier or
similarly qualified persons.
If the supply cord is damaged, it shall be
replaced by the manufacturer or its service
agent or similarly qualified person in order
to avoid a hazard.
The socket outlet for this hotplate shall be
installed near the hotplate and shall be
easily accessible.