Ambifuego KALIDO77 Istruzioni per l'uso, l'installazione e la manutenzione - Pagina 8

Sfoglia online o scarica il pdf Istruzioni per l'uso, l'installazione e la manutenzione per Camino da interno Ambifuego KALIDO77. Ambifuego KALIDO77 16.

USER INFORMATION
Turn the Left-hand control knob (B) anti-clockwise to the highest
setting (large flame).
The appliance is now burning at its highest operating output.
Running the appliance at lower setting
required.
The appliance is now operating at lower operating output.
Extinguishing the appliance back to permanent pilot
setting
Extinguishing the appliance fully
Ignite permanent pilot and run
appliance at "High" setting for
a minimum of 10 minutes as
shown previous.
With the Left-hand control
knob (B) at the highest setting,
rotate in a clock-wise direction
to
the
lower
setting
as
From any heat setting, turn the
Right-hand knob (A) in a
clockwise
direction
to
the
"Pilot" position (the smaller
flame).
From any heat setting, turn to
"Pilot" as in "Extinguishing the
appliance back to permanent
pilot setting".
Depress the same knob
slightly and turn clockwise to
"Off" position (filled circle).
8
INSTALLER INFORMATION
Flue Spillage Monitoring System
This fire is fitted with a flue spillage safety device (TTB). If the fire
shuts down during use for no apparent reason then several things
may be suspected. If a door or window has been opened creating a
draught, then pilot disturbance is the problem, and removal of the
draught should resolve this. The gas pressure reaching the fire must
also be checked. The thermocouple connection into the back of the
gas control valve may also have worked loose during installation,
simply tighten to remedy if this is the case.
If pilot disturbance is not the cause, then the TTB safety system may
be in operation. Switch the appliance OFF, check the flue and carry
out any remedial work required. Relight the fire and carry out a
spillage test. DO NOT allow the appliance to be used if it continues to
fail a spillage test.
The spillage monitoring system shall not be adjusted, modified, or put
out of operation by the installer. Any spare parts fitted MUST be of a
type supplied for the purpose by the appliance manufacturer.
If the fire is not spilling, then further guidance should be sought, using
the Troubleshooting section as a guide.
25