ambiq micro Apollo4 Blue Plus Manuale di avvio rapido - Pagina 16

Sfoglia online o scarica il pdf Manuale di avvio rapido per Computer a scheda singola ambiq micro Apollo4 Blue Plus. ambiq micro Apollo4 Blue Plus 19.

ambiq micro Apollo4 Blue Plus Manuale di avvio rapido
8.

Hardware Configuration Options

8.1
Power Supply Configuration
The Apollo4 Plus Display Shield is connected to the AMAP4PEVB hardware through each of the five GPIO
headers present on the EVB, as well as the high-speed connector, and as a result the display shield
derives its power supplies from the 5V USB supply of the EVB. The two derived power supplies are:
▪ VDD_1V9_PSU – Default 1.9V, configurable to 1.8V by shorting solder-bridge SB3
▪ VDD_3V3
The VDD_1V9_PSU rail is by default the source of power for the SHIELD_PSU rail, which is the supply for
each of the 1.9V on the display shield. However, by using solder bridges SB4 and SB5, the user can con-
figure the SHIELD_PSU rail to be supplied by an external supply, VDD_MCU of the Apollo4 EVB, or by the
default option of VDD_1V9_PSU.
▪ External Supply – Open SB4, Short SB5 on Display Shield, connect external supply to VDD_EXT on J3
of AMAP4PEVB.
▪ VDD_MCU of AMAP4PEVB – Open SB4, Short SB5, connect jumper between VDD_EXT and
VDD_MCU on J3 of AMAP4PEVB.
QS-A4PDK-1p0
Figure 5. PSU page of the Display Shield schematic
Page 16
Apollo4 Plus Display Kit Quick Start Guide
2022 Ambiq Micro, Inc.
All rights reserved.