Ambirad Tornado 600 Manuale di funzionamento, manutenzione e assistenza - Pagina 3
Sfoglia online o scarica il pdf Manuale di funzionamento, manutenzione e assistenza per Riscaldatore Ambirad Tornado 600. Ambirad Tornado 600 15. Mobile radiant heater
1 Health & safety details
Important
Read these instructions before use.
This appliance must be installed in accordance with such
regulations as are in force.
This appliance is for indoor use only.
Subject to compliance to clearance distances ventilation and flue
requirements detailed in these instructions the heater can be used
inside marquees.
Only use in a well ventilated area. See technical details Section 2.
The heater is not for domestic use.
The heater is designed for space heating only.
Do not use the heater in basements or below ground level.
This appliance is fitted with a hose and regulator.
These instructions must be given to the user.
Suitable gloves should be worn when handling this equipment.
Observe the cool down period and never handle the heater when
hot.
Never place any objects, particularly combustible materials on top
of the heater and always ensure that flues are not obstructed.
Bend knees when lifting the product via the handles for wheeling.
Gas leaks
Propane gas is highly flammable and heavier than air.
Consequently in the event of a gas leak there is a risk of explosion.
Prior to use, check gas supply connections with leak detection
solution. Never use a naked flame when checking for a gas leak.
In the event that bubbles are noted either rectify if
considered competent or consult your supplier.
Do not use the heater until the fault is rectified.
In the event of a gas leak evacuate people from the immediate
area and open doors and windows.
Do not operate electrical switches.
If a lot of gas has escaped call the Fire Service.
After ventilating the room turn off the gas valve, and disconnect
the electrical connector to the heater.
If the appliance is hot leave to cool then with the aid of a
competent person identify and rectify the source of the leak.
Gas cylinders
This heater is designed to be used with 47kg propane bottles.
Gas cylinders are heavy, never attempt to lift a cylinder, full or
empty, by yourself. Always get help.
Keep cylinders upright at all times during use, transporting and
when stored.
Liquid gas can cause severe freeze burns so avoid skin contact by
wearing gloves when making connections or handling the
cylinder. If ice is noted on the cylinder ensure that cylinder is not
leaking. If leaking is suspected do not use the cylinder.
Do not drop or knock a gas cylinder in that damaged cylinders can
be dangerous.
Do not store full or empty bottles in the operating area of the
heater and never apply heat to the cylinder.
Electrical supply
The heater is suitable for use with either a 230V/50Hz or
110V/50Hz supply. A selector switch enables the user to choose
the desired voltage. See section 3 step 4.
Only female electrical connectors compatible to the male
connectors on the rear of the unit must be used.
Always switch off and unplug the equipment when not in use.
2 Technical details
Model
Heat input gas
kW
Gas type
Gas category
Supply press
mbar
Injector size
Electrical supply
Electrical input
Weight
Hose
1.5m lg, 8mm ID approved to
Regulator
Min Room size
Required
ventilation
Countries of destination
GB, IE, BE, CH, FR, NL, ES & PT.
51
45
Propane G31
I
I
3p(37)
3p(30)
37
30
4.6
4.6
110V
400W
85kg
EN 1763-1 BS3212 (UK Only)
4kg/h
4kg/h
37mbar
30mbar
3
510m
2
1275cm
1