- ページ 2

ヒーター Ambirad VISION VSXOのPDF 組立・取扱説明書をオンラインで閲覧またはダウンロードできます。Ambirad VISION VSXO 20 ページ。 Radiant tube heaters

Introduction.
Welcome to the new range of high efficiency
AmbiRad Vision radiant tube heaters. Local
regulations may vary in the country of use and
it is the installers responsibility to ensure that
such regulations are satisfied.
All installation, assembly, commissioning and
service procedures must be carried out by
suitably qualified and competent persons to the
statutory regulations in the country of use.
When assembling, installing, commissioning
and servicing is undertaken on radiant tube
heaters specified in these instructions, due care
Document Index.

1 Installation Requirements

1.1 Health & Safety
1.2 Model definitions
2 Assembly Instructions
2.1 Tools Required
2.2 Assembly Notes
2.2.1 Tubes
2.2.2 Turbulators
2.2.3 Brackets
2.2.4 Couplers
2.2.5 U Bend
2.2.6 Reflectors
1. Installation Requirements.
Isolate any electrical supply to the
heater and controller before proceeding.
1.1
Health and Safety
AmbiRad
heaters
accordance with the relevant provisions of the
Gas Safety (Installations and Use) Regulations
1998. Due account should also be taken of any
obligations arising from the Health and Safety
at Works Act 1974 or relevant codes of
practice. In addition the installation must be
carried out in accordance with the current IEE
wiring
regulations
(Industrial & Commercial) and any other
relevant British Standards and Codes of
Practice by a qualified installer. Isolate all
electrical supplies to the heater & controller
before proceeding.
For your own safety we recommend the use of
safety boots and leather faced gloves when
must
be
installed
(BS
7671),
BS
6896
and attention is required to ensure that working
at height regulations are adhered to at the
mounting heights specified.
PLEASE READ this document prior to
installation to familiarise yourself with the
components and tools you require at the various
stages of assembly.
All Dimensions shown are in mm unless
otherwise stated.
The manufacturer reserves the right to alter
specifications without prior notice.
2.2.7 End Caps
2.2.8 Burner Assembly
2.2.9 Heat Exchanger Assembly
2.2.10 HB Damper Assembly
2.2.11 End Moulding Fixing
2.2.12 HB Damper Assembly
2.2.13 Detailed Assembly Drawings
3 User and Operating Instructions
3.1 To Start Heater
3.2 To Switch off Heater
3.3 Routine Maintenance Between Service Intervals
3.4 Frequency of Servicing
handling sharp or heavy items. The use of
protective eye wear is also recommended.
1.2
Model Definitions
VSOUT
= AmbiRad Vision U Tube Unitary
in
heater with painted induced burner, ID Fan,
aluminised
steel
insulation, tube over shields, painted canopies
and optional end covers.
VSOUH
=
Herringbone heater with painted induced burner,
Damper, aluminised steel reflectors, end caps,
insulation, tube over shields, painted canopies
and optional end covers.
VSXO
= AmbiRad Vision High efficiency U
Tube heater with forced burner, recuperative
heat exchanger, aluminised steel reflectors, end
caps, insulation, tube over shields, painted
canopies and optional end covers.
reflectors,
end
AmbiRad
Vision
U
Doc No. 700021 Page 2 of 20
caps,
Tube