アンプ AMC A65UのPDF 設置および操作マニュアルをオンラインで閲覧またはダウンロードできます。AMC A65U 8 ページ。 2 channel power amplifier for spa installations
1. Voltage Selector(115V/230VAC)
Please set the voltage to correct line
voltage 115VAC or 230VAC before
installation.
2. AC Power Receptacle
The AMC A65u is designed for using on
Spa installation applications with Ul1563
standard and with AC Power Receptacle
to go with various type of power cord &
plug.
Part Number of various power cord with
plug are listed below for ordering power
cord required (Special type of power cord
can be made by order),
14-5036, USA power cord, 3 pins plug
& standard connector
14-5037, European power cord, 3 pins
plug & 3 lugs
14-5038, USA power cord, 3 pins plug
& 3 lugs
14-5039, USA power cord, 3 pins plug
& 4P Connector
14-5040,
USA
Connector Male Housing, Male Pins
3. Power Indicator LED.
The LED will be "ON" when there is
power from Power Cord. The LED will be
"OFF" where there is no power from
Power Cord.
4. Speaker Terminals- L & R
The AMC A65u is equipped with 4-circuit
plugable Terminal Blocks allow quick
connections of the internal amplifiers to
stereo pairs of speakers. They accept
wire sizes for 14 to 28 AWG.
5. Inputs - L & R
There are two RCA phono connectors on
the rear panel that connect to the inputs
of each of the two power amplifiers.
6. Ground Terminal
This is ground terminal for hooking to
Ground of the Spa power system.
4
Power
Cord,
4P