- ページ 7

送信機 AMC AMC-360-IREPのPDF 取扱説明書をオンラインで閲覧またはダウンロードできます。AMC AMC-360-IREP 16 ページ。 Infrared methane sensor/transmitter 0-100% lel range

AMC-360-IREP 0-100% LEL Methane Sensor/Transmitter

3 PRODUCT DESCRIPTION

3.1 GENERAL DESCRIPTION

The AMC-360-IREP sensor/transmitter unit is designed to provide continuous, reliable
surveillance of surrounding air for up to 100% by LEL methane. Used with this sensor, the unit
provides a 4 to 20 mA, variable current signal which is proportional to the gas concentration
currently detected. Each sensor/transmitter unit is factory calibrated with its interconnected
sensor and is ready for field installation and operation.

3.1.1 BASIC REQUIREMENTS

OPERATING TEMPERATURE:
OPERATING PRESSURE:
HUMIDITY:
SIGNAL OUTPUT LOAD:
SIGNAL OUTPUT:

3.1.2 SENSOR DETAILS

SENSOR TYPE:
RANGE:
RESPONSE TIME:
RESOLUTION:
ZERO DRIFT:
MTBF:
Note:
Turn off power supply before removing or replacing the transmitter or sensor.
-40 to +40 ºC (-40 to +104 ºF)
Ambient atmospheric pressure.
0 to 99% RH, non-condensing.
250 ohms maximum.
Linear
Infrared
0-100% by LEL, methane
T90 <20 s @20ºC ambient
1% of measuring range
±1% full scale per month @20ºC ambient
> 5 years
1