- ページ 11

メディア・コンバーター AMCI ME15のPDF マニュアルをオンラインで閲覧またはダウンロードできます。AMCI ME15 15 ページ。 Magnetic encoder

ME15 Magnetic Encoder Manual
Revision 1.1
The following diagrams show the output waveforms for the four angular ranges of an encoder ordered with CCW
increasing output.
Figure 8: Angular Ranges with CCW increasing
The Analog output version of the ME15 can be ordered to output its minimum to maximum output over the four
Angular Ranges listed above. However, the next minimum to maximum cycle always begins at the start of the next full
turn.
Analog Voltage Output Specifications
0 – 5VDC Option
Current Consumption (No Load and 24VDC Power Supply)......25mA
Current Output............................................................10mA max.
Output Load................................................................500 Ohms min.
0 – 10VDC Option
Current Consumption (No Load and 24VDC Power Supply).......25mA
Current Output.............................................................10mA max.
Output Load................................................................1KOhm min.
20 Gear Drive, Plymouth Industrial Park, Terryville, CT 06786
page: 11
Tel: (860) 585-1254
Fax: (860) 584-1973
Web: www.amci.com