- ページ 2
水ポンプ FLOJET 04325343AのPDF マニュアルをオンラインで閲覧またはダウンロードできます。FLOJET 04325343A 4 ページ。 Quad ii diaphragm automatic washdown pump

Fresh Water
Tank
INSTALLATION
STEP 1
Remove shipping plugs from Quad pump ports. Some
water from factory testing may spill out.
STEP 2
Install inlet A and discharge B port connectors. Firmly
push slide clips C forward to lock port connectors in
place.
STEP 3
Slide rubber mounts D fully into 4 mounting tracks.
STEP 4
Mount pump vertically, with pump head down or
horizontally in an accessible location. If mounting
D.C. WIRING
STEP 1
Use 14 gauge stranded wire to 20', 12 gauge to 50',
from power source.
STEP 2
Use a 15 amp rated on-off switch on the (+) positive (red)
motor lead.
Flojet
Washdown Pump
Flojet Inlet
Strainer
Seacock
Red (+)
Fuse
Thru Deck
Fitting
"Y" Valve
vertically, motor up, attach motor mounts first, then
pump head mounts while supporting weight of pump.
STEP 5
Use 3/4" or 5/8" I.D. flexible hose (preferably braided or
reinforced). Use hose clamps on the slip-on barb hose
connectors.
STEP 6
Install a 40 mesh in line strainer in accessible location
between tank and pump inlet.
Black (–)
Switch
STEP 3
Install fuse protection in the positive lead. 12V use
15 amp fuse, 24V use 7 amp fuse, 32V use 5 amp fuse.
NOTE: The 115 Volt model may be plugged directly into
a 115V a.c. electrical outlet. A G.F.I. (ground fault interruption)
outlet and switched circuit is required near water.
C
A
B
(+)
(–)
Battery
D