SPECIFICATIONS
Mechanical
Housing material:
Strain relief:
Housing port thread:
Cable
Cable length
Operating Temperature
Higher Process Fluid
Temperatures
Obtainable with G2
Stainless Steel Meters
Storage temperature:
Power:
Type:
Voltage minimum:
Voltage maximum:
Isolated:
Primary Output (4-20mA):
Type:
Minimum:
Maximum:
Scaled Pulse Output:
Type:
External Pull Up
1
Voltage
Internal Pull Up Voltage
2
1
NOTE: Customer supplied external voltage with separate power supply and a minimum
external pull up resistance of 820 ohms.
2
NOTE: 5VDC supplied internal on the 4-20mA board, no external supply or pull up
resistor required. Internal pull up is fixed at 100K ohm
Hubble PG7. Grip range (Cable Outside Diameter)
0.11 - 0.26 in. (2.8 – 6.6 mm)
Female 1/2-20 UNF-2B (Compatible with PG7)
Belden 9363 (22 AWG-3 conductor
with drain wire and shield)
0° to +140°F (-18° to +60°C)
When installed on G2 Stainless Steel Flowmeters, see
Ambient and Fluid Temperature Limits graph on next page
for higher process fluid temperature Limits.
If wider process fluid temperature ranges are desired,
reference information on FLOMEC® Remote Kits.
-40° to +180°F (-40° to +82°C)
Open Collector (NPN), Current Sinking
5
Nylon 6/6
10 ft. (3m), provided
Loop powered
8 VDC
32 VDC
No
Loop
4 mA
25 mA
8.0 to 26 VDC
5.0 VDC